BUFFALO TURBINE WIRELESS REMOTE SYSTEM MANUAL FOR BT-CKB4
Specifications:
Receiver
(BT PN 3023) WIRELESS RECEIVER for BT-CKB3/BT-CKB4
Transmitter
(BT PN 3024) WIRELESS TRANSMITTER 4 BUTTON
Environmental
Supply Voltage: 12VDC
Signal Analog Voltage Ramp (V/Sec): 10/6
Signal Analog Ramp Range (V): 0-10 increase & 10 - 0 decrease
Functional Relays: functional relays makes/ breaks 8A ACI
Transmit Frequency: 2405-2480 MHz.
Number of Freq. Channels: 16
IP Class: IP65
Battery Type: 3 x 1.5 V - AAA alkaline
Operating Time: Approx. 15 h. with continuous usage
Operation
Operation of the controlled device is performed with the Nozzle and Throttle buttons on the transmitter. The Nozzle buttons
are used to rotate the Nozzle clock (
3
)
wise or counter clock wise (
4
)
. The Throttle buttons (
+
) increase and (
-
) decrease the
engines throttle.
-
Analog Signal Ramp Range (DCV): 0 to 10 increase (+) / 10 to 0 decrease (
-)
-
Releasing the + or - buttons at any time during an increase/decrease command will result in the control voltage to
remain at a proportional value between 0 and 10 volts.
-
At any time the operator can press both + and - buttons simultaneously to return the variable output to 0 volts
resulting in the engine's throttle be set back to low idle.
Pairing Transmitter (TX) to Receiver (RX)
This procedure should be used to pair a single transmitter to the receiver. If you need multiple transmitters paired to this
Receiver contact Buffalo Turbine at 716-592-2700 for assistance.
The following steps will completely erase any previously stored transmitter out of the receiver’s memory making them
obsolete. You have 10 seconds to complete these procedures after turning the engine key switch to the run position.
1.
Turn Engine key switch to run position, supplying power to receiver.
2.
Firmly press and hold transmitter buttons Throttle increase (+), Nozzle (CCW) and Throttle Decrease (-) for at least
three (3) seconds simultaneously to complete pairing process.
If a valid code from an already registered TX is received, the receiver will go directly into normal operating mode. This is to
speed up the startup time.
NOTE: Breaking any warranty seal will void the equipment’s warranty, consult with Buffalo Turbine at 716-592-2700