UK
Trouble Shooting
Fault
Probable Cause
Action Required
Indicator Light does not
come on & Merchandiser
does not heat up
Power is not switched at socket
Turn power on at socket
Plug fuse has failed
Change fuse
Power cable is damaged
Call BUFFALO dealer for repair
service
Thermostat has failed
Call BUFFALO dealer for repair
service
Indicator Light comes on but
Warmer does not heat up
Heating element has failed
Call BUFFALO dealer for repair
service
Thermostat has failed
Call BUFFALO dealer for repair
service
Technical Specifications
Code
Voltage
(Volts)
Power
(Watts)
Current
(Amps)
Dimensions
(mm)
Weight
(Kgs)
CK915
220V-240V/50Hz
800w
3.4
311 x 554 x 376mm
12.4
CK916
220V-240V/50Hz
800w
3.4
376 x 554 x 376mm
14.4
Electrical Wiring
This appliance is supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse.
The plug is to be connected to a suitable mains socket
The appliance is wired as follows:
•
Live wire (coloured brown) to terminal marked L
•
Neutral wire (coloured blue) to terminal marked N
•
Earth wire (coloured green/yellow) to terminal marked E
This appliance must be earthed, using a dedicated earthing circuit
If in doubt, consult a qualified electrician. Electrical isolation points must be kept clear of any
obstructions. In the event of any emergency disconnection being required they must be readily
accessible
Summary of Contents for CK915
Page 31: ......
Page 32: ...CK915_CK916_ML_A5_v2...