CP10.241, CP10.241-C1, CP10.241-S1,
CP10.241-S2, CP10.242
CP-Series
24V,
10A,
240W,
S
INGLE
P
HASE
I
NPUT
Aug. 2017 / Rev. 1.4a DS-CP10.241-EN
All values are typical at 24V, 10A, 230Vac, 50Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
Fig. 3-3
Input current vs. output current at
24V output voltage
Fig. 3-4
Power factor vs. output current at
24V output voltage
12A
1
2
3
4
5
6
7
8
9
0
0.5
1.0
1.5
2.0
2.5
3A
Input Current, typ.
10 11
a) 100Vac
b) 120Vac
c) 230Vac
b
a
c
Output Current
Power Factor, typ.
1
2
3
4
5
6
7
8
9
12A
0.75
0.8
0.85
0.9
0.95
1.0
10 11
Output Current
(a) 100Vac,
(b) 120Vac,
(c) 230Vac
(a)
(b)
(c)
4.
DC-I
NPUT
DC input
Nom.
DC 110-150V
±20%
For CP10.241, CP10.241-C1, CP10.241-S1, CP10.241-
S2
Nom.
DC 110-300V
±20%
For CP10.242
DC input range
Min.
88-180Vdc
For CP10.241, CP10.241-C1, CP10.241-S1,
CP10.241-S2, continuous operation
Min.
88-360Vdc
For
CP10.242
DC input current
Typ.
2.35A
At 110Vdc, at 24V, 10A
Typ.
0.84A
At 300Vdc, at 24V, 10A
Allowed Voltage L/N to Earth
Max.
375Vdc
Continuous, according to IEC 62477-1
Turn-on voltage
Typ.
80Vdc
Steady state value
Shut-down voltage
Typ.
70Vdc
Steady state value
Typ.
55Vdc
Dynamic value for maximal 250ms
Fig. 4-1
Wiring for DC Input
Instructions for DC use:
+
-
Load
L
PE
+
-
Power Supply
AC
DC
Battery
N
a)
Use a battery or a similar DC source. A supply from the
intermediate DC-bus of a frequency converter is not
recommended and can cause a malfunction or damage
the unit.
b)
Cpole to L and –pole to N.
c)
Connect the PE terminal to an earth wire or to the
machine ground.
5/30