CP10.241, CP10.241-C1, CP10.241-S1,
CP10.241-S2, CP10.242
CP-Series
24V,
10A,
240W,
S
INGLE
P
HASE
I
NPUT
Aug. 2017 / Rev. 1.4a DS-CP10.241-EN
All values are typical at 24V, 10A, 230Vac, 50Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
Fig. 6-1
Output voltage vs. output current,
typ.
Fig. 6-2
Dynamic output current capability,
typ.
Output Voltage
0
0
12.5
4
8
12
28V
16
20
24
20A
7.5
2.5
5
10
15 17.5
Adjustment
Range
Output Current
Continuous
current
Factory
setting
Hiccup
PLUS
mode
Output Voltage
(dynamic behavior, < 12ms)
0
0
4
8
12
28V
16
20
24
50A
20
10
30
40
5
15
25
35
45
Adjustment
Range
Output Current
Fig. 6-3
Short-circuit on output, Hiccup
PLUS
mode, typ.
Output
Current
0
14A
18s
18s
18s
2s
2s
2s
t
Short -circuit
Normal
operation
Normal
operation
7.
H
OLD
-
UP
T
IME
AC 100V
AC 120V
AC 230V
Hold-up Time
Typ.
73ms
73ms
73ms
At 24V, 5A, see Fig. 7-1
Min.
55ms
55ms
55ms
At 24V, 5A, see Fig. 7-1
Typ.
37ms
37ms
37ms
At 24V, 10A, see Fig. 7-1
Min.
28ms
28ms
28ms
At 24V, 10A, see Fig. 7-1
Fig. 7-1
Hold-up time vs. input voltage
Fig. 7-2
Shut-down ehaviour, definitions
0
10
20
30
40
80ms
90
120
155
190
230Vac
Input Voltage
50
60
Hold-up Time
70
a
b
c
d
a) 24V 5A typ.
b) 24V 5A min.
c) 24V 10A typ.
d) 24V 10A min.
- 5%
Hold-up Time
Zero Transition
Output
Voltage
Input
Voltage
8/30