CU-EMA+
9.2 Technical Data
Technical Data
Type tested:
DNV GL
rules for classification
Ships, offshore units, and high speed and light craft
Certificate no.: TAA00002RE
Lloyd’s Register
Type Approval
System, Test Specification Number 1 - March 2019
Certificate no.: LR2008137TA
Ambient categories as per DNVGL-CG-0339:
Temperature: A
Humidity B
Vibration A
EMC A
Housing: B
Environmental categories as per LR:
ENV1, ENV2
Switch cabinet
Dimensions (h x w x d):
500 x 500 x 300 mm
Material
Sheet steel, RAL 7035, single door
Degree of protection
IP44
Weight
31 kg
Climatic conditions
Ambient temperatures:
+5 °C … +50 °C
Storage temperatures:
-20 °C … +40 °C
Cooler Data
Ready for operation
after max. 10 minutes
Gas output dew temperature preset:
adjustable:
5 °C
2 °C…20 °C
Static dew point stability:
throughout the specification range:
+- 0.1 K
+- 1.5 K
Inlet dew point max.:
+70 °C
Gas input temperature on heat exchanger max. 140 °C
Rated cooling capacity (at 25 °C):
110 kJ/h
Other data
Gas connections:
see flow diagram
Parts in contact with media:
PVDF, stainless steel, PTFE, Norprene, Viton, epoxy resin
Electrical data
Supply:
115 VAC/230 VAC, 50/60Hz, 16A,
cable clamps, cable cross-section 1.5…2.5 mm
²
shielded
Cooler:
(power peristaltic pump)
230 VAC. 300 VA
Status contact cooler, moisture and optional
regulated heated line
max. 230 VAC, 24 VDC, 2 A, 50 VA,
cable clamps, cable cross-section 0.75…2.5 mm
²
shielded
Max. additional consumers (e.g. heated probe)
115 VAC/230 VAC, 800 VA,
cable clamps, cable cross-section 1.5…2.5 mm
²
Transfer clamps (e.g. status contact heated probe) Cable clamps, cable cross-section 0.75…2.5 mm
²
9.3 Technical Data - Options
Controller for heated line
Temperature,
preset:
adjustable:
180 °C
40 °C … 200 °C
Flow:
max. 115 VAC/230 VAC 1600 VA
cable clamps, cable cross-section 1.5…2.5 mm
²
Sensor type:
Pt100, 2-wire
30
Bühler Technologies GmbH
BE440029 ◦ 10/2020