Technical Data Peristaltic Pumps CPsingle / CPdouble
Nominal voltage / power input:
at T
amb
= 20 °C and under load
230 V 50 Hz, 0.025 A
115 V 60 Hz, 0.044 A
24 V DC, 0.1 A
*)
Flow rate:
0.3 L/h (50 Hz) / 0.36 L/h (60 Hz) with standard hose
1.0 L/h (50 Hz) / 1.2 L/h (60 Hz)
13 ml/h
61 ml/h
25 ml/min or 1.5 L/h (for 24 V DC)
Inlet vacuum:
max. 0.8 bar
Inlet pressure:
max. 1 bar
Output pressure:
1 bar
Protection class:
IP 44 (housing version)
IP 40 (built-in version)
Ambient temperatures:
T
amb
= 55 °C (housing version)
T
amb
= 60 °C (built-in version)
0 … 50 °C (FM versions)
Cable lengths:
2 m (housing version 115/230 V)
500 mm (built-in version 115/230 V)
250 mm (24 V DC)
Materials
Hose:
Connections:
Norprene (standard), Marprene, Fluran
PVDF
FM approval no.:
3058168
*)
Life 24 V DC 3000 h
15
Bühler Technologies GmbH
BE450021 ◦ 01/2017