0330
p. 2/12
Circuit function
A
2/2 way direct-acting
solenoid valve, normally
closed
B
2/2 way direct-acting
solenoid valve, normally
open
C
3/2 way direct-acting
solenoid valve, normally
closed
D
3/2 way direct-acting
solenoid valve, normally
open
E
3/2 way mixing solenoid
valve
F
3/2 way direct-acting, dis-
tribution solenoid valve
T
3/2 way direct-acting
solenoid valve, flow direc-
tion optional
2 (A)
1 (P)
2 (B)
1 (P)
2(A)
1(P)
3(R)
12
2(B)
1(P) 3(R)
10
2(A)
1(P1) 3(P2)
4(A) 2(B)
1(P)
NC NO
Response times [ms]:
Measured at valve outlet at 6 bar and +20 °C
Opening:
Pressure rise 0 to 90 %,
Closing:
Pressure drop 100 to 10 %
Pressure range and flow rate for metal body
Circuit function
DN K
V
value water [m³/h]:
Standard
1)
Impulse
2)
DC
AC
[50 or 60 Hz]
Pressure range
4)
[bar]
Vacuum
3)
Pressure range
4)
[bar]
Pressure range
4)
[bar]
A / B / C / D / F
2.0
0.08
0.11
0-16
5)
-0.98-10
0-16
5)
3.0
0.14
0.18
0-10
-0.98-6
0-10
4.0
0.17
0.23
0-5
-0.98-3
0-5
5.0
0.29
0.29
0-2.5
-0.98-1
0-2.5
E
2.0
0.08
0.11
0-10
-0.98-8
0-10
3.0
0.14
0.18
0-6
-0.98-5
0-6
4.0
0.17
0.23
0-3
-0.98-2.5
0-3
5.0
0.29
0.29
0-1.5
-0.98-1
0-1
T
2.0
0.08
0.11
0-12
-0.98-8
0-10
3.0
0.14
0.18
0-8
-0.98-5
0-6
4.0
0.17
0.23
0-4
-0.98-2.5
0-5
5.0
0.29
0.29
0-2.5
-0.98-1
-
Pressure range and flow rate for plastic body
Circuit function
DN K
V
value water
[m
3
/h]
6)
Standard
1)
Impulse
2)
Pressure range
4)
[bar]
AC [50 or 60 Hz]
Pressure range
4)
[bar] DC
Vacuum
Pressure range
4)
[bar]
Pressure range
4)
[bar]
A / B / C / D / F
2.0 0.13
0-16
5)
0-12
-0.98-10
0-12
3.0 0.25
0-10
0-8
-0.98-6
0-8
4.0 0.30
0-5
0-4
-0.98-3
0-4
5.0 0.40
0-4.5
0-3
-0.98-1
0-3
E / T
2.0 0.13
0-10
0-7
-0.98-7
0-7
3.0 0.25
0-6
0-4
-0.98-5
0-4
4.0 0.30
0-3
0-2
-0.98-2.5
0-2
1)
Rated power consumption 8 W
2)
Inrush power 11 W
3)
Vacuum possible for all seal materials
4)
Pressure values [bar] with respect to atmospheric pressure
5)
For seal material FKM and FFKM the max. mediums pressure is 12 bar
6)
At frequency DC the K
V
value is reduced till 10 % to fulfil the function
Technical data
(continued)
Electrical connection
Pin terminal acc. to DIN EN 175301-803 Form A for cable
pug Type 2508/2509
(also on request with moulded cable or terminal box)
Protection class
IP65 with Cable Plug
Coil insulation class
H
Installation
As required, preferably with actuator upright
Weight [kg]
with metal body
with plastic housing
0.47
0.40
Standard power consumption
Frequency AC
Frequency DC
Inrush [VA]
Hold [VA]
Operation [W]
Cold [W]
Warm [W]
30
15
8
11
8
Impulse (inrush winding)
Frequency AC
Frequency DC
Hold [VA]
Operation [W]
Cold [W]
Warm [W]
20
11
11
8
Response times
Orifice [mm]
Frequency AC
Frequency DC
Opening [ms]
Closing [ms]
Opening [ms]
Closing [ms]
2-4
8-15
8-15
10-20
10-20