0330 Ex
p. 4/12
Additional options
Option
Variable
Code
Description
Impulse version
CF02
Bistable magnetic system with inrush and drop-off coil; Continuous op-
eration or operation with short current pulses (min. 150 ms) possible
Oxygen versions
NL02
Suitable for applications with oxygen
(non-metal materials that are in contact with the medium, are tested and
approved according to BAM)
Increased purity requirements e.g. oil, grease and
silicone-free
NL50/NL05
Wetted parts are specially cleaned and packaged in accordance with
the valves
Increased tightness requirements
PCxx
Standard units are tested at 10
-2
mbar x l / sec; feasible up to 10
6
mbar
Electrical feedback
LF02 / LF03
See Type 1060
High-power electronics
CZ05
Inrush power 60 W, nominal holding current 3 W; with plastic versions
100 % ED is now feasible
Vacuum version
NA02
Suitable for vacuums up to -0.98 bar
Increased purity and tightness requirements
NA03
Wetted parts are specially cleaned and leak tested to 10
-4
mbar x l/sec
Increased purity and tightness requirements and
vacuum version
NA01
Wetted parts are specially cleaned and leak tested up to 10
-4
mbar x l/
sec and suited for vacuum up to -0.98 bar
Coil with reduced power (5 W)
Devices have lower pressure range; with plastic versions 100 % ED is
now feasible
Cable plug
JFxx / JGxx
Cable plug is included in delivery.
Cable plug versions (acc. to DIN EN 175301-803 Form A),
see datasheet Type 2508 and 2509
Approvals
PD01
CSA General Purpose valve
PD02
CSA General Purpose valve
UL recognized General Purpose valve
PD24
UL listed General Purpose valve
CSA General Purpose valve
FM non-incendive for class I / II / III Div.2 T4
PD45
FM explosionproof for class I Div. 1 and dust-ingnitionproof for class II /
III Div. 1 T4
CSA General Purpose valve for hazardous location class I / II Div. 2 and
class III T4
PD07
DNV-GL (formerly Germanischer Lloyd)
possible conformities (depending on the assembly)
EAC, drinking water, FDA