0330 Ex
p. 8/12
Technical data
(continued)
Pressure range and flow rate for metal body
Circuit function
DN
K
V
value water [m
3
/h]
Standard
Pressure range
2) 3)
[bar]
Vacuum
Pressure range
[bar]
A / B / C / D / F
2.0
0.11
0-16
-0.98 – 10
3.0
0.18
0-10
-0.98 – 6
4.0
0.23
0 – 5
-0.98 – 3
5.0
0.29
0 – 4
-0.98 – 2.5
E
2.0
0.11
0 – 10
-0.98 – 8
3.0
0.18
0 – 6
-0.98 – 5
4.0
0.23
0 – 3.5
-0.98 – 2.5
5.0
0.29
0 – 3
-0.98 – 2
T
2.0
0.11
0 – 10
-0.98 – 8
3.0
0.18
0 – 6
-0.98 – 5
Pressure range and flow rate for plastic body
Circuit function
DN
K
V
value water [m
3
/h]
Standard
Pressure range
2) 3)
[bar]
Vacuum
Pressure range
[bar]
A / B / C / D / F
2.0
0.13
0-16
-0.98 – 10
3.0
0.25
0 – 10
-0.98 – 6
4.0
0.30
0 – 5
-0.98 – 3
5.0
0.40
0 – 4.5
-0.98 – 1
E / T
2.0
0.13
0-10
-0.98 – 7
3.0
0.25
0 – 6
-0.98 – 5
4.0
0.30
0 – 3
-0.98 – 2.5
1)
Measured at +20 °C, 1 bar
2)
pressure at valve inlet and free outlet.
2)
Devices with FKM or FFKM diaphragm are reduced to a max. pressure of 12 bar
3)
Pressure data [bar]: Measured as overpressure to the atmospheric pressure