EARTHING REGULATIONS
This compressor has to be earthed while in use in order to protect the operator against
electrical shocks. The compressor is provided with a two core cable plus an earth. The
electrical connection has to be made by a qualified technician.
We recommend never disassembling the compressor and neither making any other
connections into the pressure regulator. Repairs should be carried out by authorized support
services or by other qualified centers.
Never forget that the earthing core is the green or the
yellow/green wire. Never connect this green wire to a terminal
under load.
Before replacing the plug of the feed, make sure that the earth cable is connected.
if in doubt, please call in a qualified electrician and have earthing checked
Power supply
> The compressor is equipped with a mains cable with shock-proof plug. This can be
connected to any 230V~/50Hz shock proof socket which is protected by a 16A fuse.
> Long supply cables, extensions, cable reels etc. cause a drop in voltage and can impede
motor start-up. Do not use cables longer than 10m.
RATING LABEL