ONE-PIECE DOOR WITHOUT TRACK

A 2x4 on its side is convenient for setting an ideal
door-to-rail distance. 

• Remove foam packaging.

• Raise the opener onto a stepladder. You will need

help at this point if the ladder is not tall enough.

• Open the door all the way and place a 2x4 on its

side on the top section of the door beneath the rail.

• The top of the door should be level with the top of

the motor unit. Do not position the opener more
than 4" (10 cm) above this point.

INSTALLATION STEP 4

Position the Opener

Follow instructions which apply to your door type as
illustrated.

SECTIONAL DOOR OR ONE-PIECE DOOR WITH
TRACK

A 2x4 laid flat is convenient for setting an ideal 
door-to-rail distance.

• Remove foam packaging.

• Raise the opener onto a stepladder. You will need

help at this point if the ladder is not tall enough.

• Open the door all the way and place a 2x4 laid flat

on the top section beneath the rail.

• If the top section or panel hits the trolley when you

raise the door, pull down on the trolley release arm
to disconnect inner and outer sections. Slide the
outer trolley toward the motor unit. The trolley can
remain disconnected until Installation Step 12
is completed.

Trolley 
Release Arm

ENGAGED

RELEASED

To prevent damage to garage door, rest garage door
opener rail on 2x4 placed on top section of door.

WARNING

CAUTION

WARNING

WARNING

Rail

Door

2x4 is used to determine 
the correct mounting height 
from ceiling.

Header
Bracket

Top of Door

2x4 is used to determine 
the correct mounting height 
from ceiling.

Summary of Contents for 1345BM 1/3HP

Page 1: ...se read this manual and the enclosed safety materials carefully Fasten the manual near the garage door after installation The door WILL NOT CLOSE unless the Protector System is connected and properly...

Page 2: ...c chart 30 Programming 31 32 To add or reprogram a hand held remote control 31 To erase all codes 31 3 Button remotes 31 To add reprogram or change a Keyless Entry PIN 32 Repair Parts 33 34 Rail assem...

Page 3: ...your garage door Before you begin Disable locks Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or binding 1 Lift t...

Page 4: ...u proceed with the installation of your opener Access Door Safety Reversing Sensor Safety Reversing Sensor Slack in chain tension is normal when garage door is closed Gap between floor and bottom of d...

Page 5: ...cket Door Control Button Motor Unit with Light lens 2 Safety Reversing Sensors 1 Sending Eye and 1 Receiving Eye with 2 Conductor White White Black Bell Wire attached Safety Sensor Bracket 2 One Piece...

Page 6: ...obtain more chain slack Insert the second washered bolt CAUTION Use only the bolt previously removed from motor unit Tighten both bolts securely through the rail into the motor unit as shown Install...

Page 7: ...uce the risk of SEVERE INJURY or DEATH WARNING WARNING WARNING 1 READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS 2 Install garage door opener only on properly balanced and lubricated garage...

Page 8: ...the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 9 for ceiling installation To prevent possible SERIOUS INJURY...

Page 9: ...age Door Header Wall Garage Door UP CEILING MOUNT ONLY Wall Mounting Holes Optional Wall Mounting Holes The nail hole is for positioning only You must use lag screws to mount the header bracket UP CEI...

Page 10: ...ou ll need help Have someone hold the opener securely on a temporary support to allow the rail to clear the spring Position the rail bracket against the header bracket Align the bracket holes and join...

Page 11: ...or setting an ideal door to rail distance Remove foam packaging Raise the opener onto a stepladder You will need help at this point if the ladder is not tall enough Open the door all the way and place...

Page 12: ...the motor unit to the structural support 2 Cut both pieces of the hanging bracket to required lengths 3 Drill 3 16 pilot holes in the structural supports 4 Attach one end of each bracket to a support...

Page 13: ...wo screw terminals on the back of the door control by color white wire to 2 and white red wire to 1 2 Fasten the Lighted Door Control Button securely with 6ABx1 1 2 screws If installing into drywall d...

Page 14: ...vent possible SERIOUS INJURY or DEATH from a falling garage door If possible use emergency release handle to disengage trolley ONLY when garage door is CLOSED Weak or broken springs or unbalanced door...

Page 15: ...he black line wire to the screw on the brass terminal the white neutral wire to the screw on the silver terminal and the ground wire to the green ground screw The opener must be grounded Reinstall the...

Page 16: ...r Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens The mounting brackets are designed to clip onto the track of sectional g...

Page 17: ...p hugging the back edge of the track as shown in Figure 1 If your door track will not support the bracket securely wall installation is recommended Wall installation Figure 2 3 Place the bracket again...

Page 18: ...of alignment or obstruction If the green indicator light in the receiving eye is off dim or flickering and the invisible light beam path is not obstructed alignment is required Loosen the sending eye...

Page 19: ...ollows depending on your door s construction Metal or light weight doors using a vertical angle iron brace between the door panel support and the door bracket Drill 3 16 fastening holes Secure the doo...

Page 20: ...INUM STEEL DOORS WITH GLASS PANEL ETC NOT PROVIDED ONE PIECE DOORS Please read and comply with the warnings and reinforcement instructions on the previous page They apply to one piece doors also Cente...

Page 21: ...re 3 Hole alignment alternative If holes in curved arm are above holes in straight arm disconnect straight arm Cut about 6 15 cm from the solid end Reconnect to trolley with cut end down as shown Brin...

Page 22: ...hers 5 16 Ring Fastener Straight Arm Bolts 5 16 18x7 8 Door Bracket Clevis Pin 5 16 x1 1 4 Curved Door Arm Press the Door Control push button The trolley will travel to the fully closed position Manua...

Page 23: ...ined in Adjustment Step 2 If the door does not close completely Increase down travel Turn the down limit adjustment screw counterclockwise One turn equals 2 5 cm of travel If door still won t close co...

Page 24: ...small adjustments until the door completes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the minimum amount required to close the...

Page 25: ...un the opener through 3 or 4 complete travel cycles to test adjustment If the unit continues to fail the Safety Reverse Test call for a trained door systems technician IMPORTANT SAFETY CHECK Test the...

Page 26: ...he Multi Function Door Control is activated Bulb size is 100 watts maximum SAFETY SIGNAL light feature Lights will also turn on when someone walks through the open garage door With a Multi Function Do...

Page 27: ...ossible SERIOUS INJURY or DEATH from a falling garage door If possible use emergency release handle to disengage trolley ONLY when garage door is CLOSED Weak or broken springs or unbalanced door could...

Page 28: ...ved including interference that may cause undesired operation MAINTENANCE SCHEDULE Once a Month Manually operate door If it is unbalanced or binding call a trained door systems technician Check to be...

Page 29: ...to force or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel Refer to Adjustment Step 1 Adjust the UP...

Page 30: ...r control touch wires together If motor unit activates replace door control If motor unit does not activate disconnect door control wires from motor unit Momentarily short across red and white termina...

Page 31: ...erate your garage door 3 Release the button when the motor unit lights blink It has learned the code If light bulbs are not installed two clicks will be heard To Add or Reprogram a Hand held Remote Co...

Page 32: ...mporary PIN You may authorize access by visitors or service people with a temporary 4 digit PIN After a programmed number of hours or number of accesses this temporary PIN expires and will no longer o...

Page 33: ...n fastener 9 41A5034 Safety sensor kit receiving and sending eyes with 3 9 m 2 conductor bell wire attached 10 178B34 Straight door arm section 11 178B35 Curved door arm section 12 41A5266 1 Safety se...

Page 34: ...abels 6 175B88 Light socket 7 108D36 Lens 8 30B533 Capacitor 1 3HP 9 12A373 Capacitor bracket 10 41A3150 Terminal block w screws 11 41D3058 Universal replacement motor bracket assy Complete with Motor...

Page 35: ...ted when desired 376LG SAFETY SIGNAL 2 Button Remote Control Includes visor clip Outside Keylock Opens the garage door automatically from outside when remote control is not handy Outside Quick Release...

Page 36: ...rranty repair which upon receipt by Seller are confirmed to be defective and covered by this limited warranty will be repaired or replaced at Seller s sole option at no cost to you and returned pre pa...