INSPECTING / CLEANING BURNER AND GAS
ORIFICES
(CONT.)
IGNITER / ELECTRODE CHECK
With all control knobs set to “OFF”, check each igniter individually for presence of spark at electrode. In turn, push each control knob in fully and
turn slowly about a 1/4 turn to the left (counter-clockwise) until a click is heard; the trigger hitting the strike block should produce a blue spark at the
electrode tip. Return control knob to “OFF” before checking next igniter.
BURNER OPERATION CHECK
NOTE:
Upon
first assembly the gas lines and burner will be full of air. In order for the burner to light properly, the lines must fill with gas. It may
require several attempts at lighting the burner before you are successful.
1. With power burner control knobs in “OFF” position, turn on the Gas supply.
2. Light any burner by pushing its control knob in fully and slowly (3 to 4 seconds) turning it about 1/4 turn to the left (counter-clockwise) until a click
is heard. The 3 to 4 second duration should provide enough gas to light the burner. If the burner does not light, immediately return the control knob
to “OFF”, wait several minutes for the gas to disperse, and repeat the process. After burner lights successfully, turn control knob to “OFF”.
3. Repeat process for the next control knob/igniter, ensuring that the other knob is in “OFF” position as you perform the check.
4. If any burners fail to light after several attempts, discontinue gas supply at source and re-inspect for obstructions to gas flow and orifices.
NOW YOUR POWER BURNER IS READY TO USE!
Before first use and at the beginning of each season:
1. Please read Safety, Lighting and Operating Instructions carefully.
2. Check gas orifices, burner tube and burner ports for any obstructions.
3. PERFORM GAS LEAK CHECK – REFER TO
PAGE 2
.
11
Summary of Contents for 96000
Page 17: ...EXPLODED ILLUSTRATION 16...