User Guide
186
www.bull.com
Cable Routing
When you add or remove components from your server, make sure your cables are
routed correctly before reinstalling the server cover. Use caution to make sure no
cables or wires are pinched and that the airflow from the fans is not blocked. Use the
figures below to determine the correct cable routing.
For readability, separate figures for power cable routing and data cable routing are
included below. Make sure all necessary power and data cables are connected and
routed as shown. Dashed lines in the drawings indicate a location where a cable is
routed beneath a component and each connector end is labeled with the same letter.
Power Cable Routing
Figure 134: Power Cable Routing
Note: The power cable to the two hard drives and the
optical drive (C, D, E) is a single daisy chain cable.
A: Processor power
E: Connector closest to power supply to HDD1
B: Main power
F: Right system blower fan
C: End connector to optical drive
G: Left system blower fan
D: Center connector to HDD0
H: PCI cooling fan
B
A
C
D
F
G
H
E