User Guide
232
www.bull.com
Creating Partition Size
The minimum size for the partition where the system is to be installed can be calculated
from the following formula.
Size necessary to install the Paging File Size + Dump File Size
Size necessary to install the system= 2900 MB
Paging File Size (Recommended)= Mounted Memory Size × 1.5
Dump file Size= Mounted Memory Size + 12 MB
Caution
■
The above paging file size is necessary for collecting debug
information (memory dump). If you set the default value of
paging file size smaller than the 'recommended' value, the
accurate debug information (memory dump) may not be col-
lected.
■
The maximum paging file size which can be set on one parti-
tion is 4095 MB. If the above paging file size exceeds
4095 MB, specify 4095 MB for the paging file size.
■
If you install any application program or the like, add neces-
sary space to the partition to install these programs.
For example, if the mounted memory size is 512 MB, the minimally required partition
size will be calculated by the above formula as follows:
2900 MB + (512 MB * 1.5) + (512 MB + 12 MB) = 4192 MB
Installing Windows Server 2003
This section describes how to setup the system using Express Setup.
1.
Turn the power of peripheral devices on, and then turn on the system.
Note: Connect the hard disk drive on which the operating
system is not going to be installed after installing the operating
system.
2.
Insert the ExpressBuilder disc into the optical disc drive. The “Choose Your
Language” prompt displays.
3.
Click on one of the flags to choose a language. The Express Setup home page
displays.
■
Express Setup
: click here to install the Operating System.
■
Tools
: click here to access DOS tools
Summary of Contents for NovaScale R410 E1
Page 1: ...NovaScale T810 E1 T830 E1 R410 E1 User s Guide NOVASCALE REFERENCE 86 A1 15FA 00 ...
Page 2: ......
Page 34: ...User Guide 34 www bull com Motherboard Motherboard Layout Figure 14 Motherboard Layout ...
Page 53: ...User Guide 53 www bull com SAS Hard Disk Drive Capacity 73GB minimum 15000 RPM RAID support ...
Page 318: ......
Page 319: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 15FA 00 ...