Problems with the System
Fail to power on the system:
■
Is the system is properly supplied with power?
- Check if the power cord is connected to a power outlet (or UPS) that meets the
power specifications for the system.
- Check the power cord for broken shield or bent plugs.
- Make sure the power breaker for the connected power outlet is on.
- If the power cord is plugged to a UPS, make sure the UPS is powered and it out-
puts power. See the manual that comes with the UPS for details.
■
Did you press the POWER/SLEEP switch?
- Press the POWER/SLEEP switch on the front of the system to turn on the
power (the POWER/SLEEP lamp lights).
Fail to power off the system
■
Is the power switch enabled?
- Restart the system and start the BIOS setup utility
No screen display appears and beep occurs.
■
Is the DIMM board installed securely?
- Check whether the DIMM board is inserted into the mating connector securely.
- Make sure the jumper switches have been returned to their original positions
after CMOS clearing. for the positions of the jumper switches.
POST fails to complete:
■
Is the memory size large?
- The memory check may take a few seconds if the memory size is large. Wait for
a while.
■
Did you perform any keyboard or mouse operation immediately after you started
the system?
- If you perform any keyboard or mouse operation immediately after start-up,
POST may accidentally detect a keyboard controller error and stops proceeding.
In such a case, restart the system once again. Do not perform any keyboard or
mouse operation until the BIOS start-up message appears when you restart the
system.
■
Does the system contain appropriate memory boards or PCI devices?
- Operation of the system with unauthorized devices is not guaranteed.
Summary of Contents for NovaScale R410 E1
Page 1: ...NovaScale T810 E1 T830 E1 R410 E1 User s Guide NOVASCALE REFERENCE 86 A1 15FA 00 ...
Page 2: ......
Page 34: ...User Guide 34 www bull com Motherboard Motherboard Layout Figure 14 Motherboard Layout ...
Page 53: ...User Guide 53 www bull com SAS Hard Disk Drive Capacity 73GB minimum 15000 RPM RAID support ...
Page 318: ......
Page 319: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 15FA 00 ...