background image

Return Authorization

The following steps must be completed before Bullard will accept any returned goods. Please read carefully.
Follow the steps outlined below to return goods to Bullard for repair or replacement under warranty or for paid repairs:
1. Contact Bullard Customer Service by telephone or in writing at:
 

Bullard

 

1898 Safety Way

 

Cynthiana, KY 41031-9303

 

Toll-free: 877-BULLARD (285-5273)

 

Phone: 859-234-6616

In your correspondence or conversation with Customer Service, describe the problem as completely as possible. For your convenience, your Customer Service 
specialist will try to help you correct the problem over the phone.
2. Verify with your Customer Service specialist that the product should be returned to Bullard. Customer Service will provide you with written permission and a 
return authorization number as well as the labels you will need to return the product.
3. Before returning the product, decontaminate and clean it to remove any hazardous materials which may have settled on the product during use. Laws and/or 
regulations prohibit the shipment of hazardous or contaminated materials. Products suspected to be contaminated will be professionally discarded at the 
customer’s expense.
4. Ship returned products, including those under warranty, with all transportation charges pre-paid. Bullard cannot accept returned goods on a freight collect 
basis.
5. Returned products will be inspected upon return to the Bullard facility. Bullard Customer Service will telephone you with a quote for required repair work 
which is not covered by warranty. If the cost of repairs exceeds stated quote by more than 20%, your Customer Service specialist will call you for authorization 
to complete repairs. After repairs are completed and the goods have been returned to you, Bullard will invoice you for actual work performed.

Americas:

E.D. Bullard Company

1898 Safety Way  
Cynthiana, KY  41031-9303
Toll free: 877-BULLARD (285-5273)
Tel: 859-234-6616 
Fax: 859-234-8987

www.bullard.com

Europe:

Bullard GmbH

Lilienthalstrasse 12
53424 Remagen • Germany
Tel: +49-2642 999980 
Fax : +49-2642 9999829

www.bullardextrem.com

Asia-Pacific:

Bullard Asia Pacific Pte. Ltd.

LHK Building
701, Sims Drive, #04-03 
Singapore 387383
Tel: +65-6745-0556 
Fax: +65-6745-5

www.bullard.com

©2011 Bullard. All rights reserved.

6081256210D (1011)

ISO 9001 

certified

Parts and Accessories

Adjustable Cool Tubes

Cold Only 

Hot/Cold 

Dual-Cool 

Coupling Type

AC100030 

HC240030 

DC5040 

1/4” Industrial Interchange 

1/4” Snap-Tite, steel

AC100030B 

HC240030B 

DC5040B 

1/4” Industrial Interchange (Brass) 

1/4” Snap-Tite, brass

AC100030S 

HC240030S 

DC5040S 

1/4” Industrial Interchange (Stainless Steel) 

1/4” Snap-Tite,  stainless steel

AC100031 

HC240031 

DC5041 

1/4” Schrader 

 

AC100032  HC240032 DC5042 

 

AC100033  

HC240033 

DC5043

AC100034  

HC240034 

DC5044

FRIGITRON2000
FRIGITRON2000B

V5 Coiled Hose

V52530, V55030, 

V52531, V55031, 

V52532, V55032

Air Supply Hose

4696,46913, 46915,  

5454, 5457, 5458

Summary of Contents for RT Series

Page 1: ...ard offers the appropriate approved breathing tube flow control device and air supply hose to connect the RT Series respirator to these breathing air sources RT Series respirators are approved by NIOSH for use with optional Bullard climate control devices Contact Bullard or our local authorized distributor for more information about these and other accessories for RT Series respirators All Bullard...

Page 2: ...r critical User s Instructions and or specific use limitations apply Refer to User s Instructions before donning 2 CAUTIONS AND LIMITATIONS CF CONTINUOUS FLOW SA SUPPLIED AIR 1 PROTECTION TC PROTECTION1 MODEL ALTERNATE HOOD A SSEMBLIES ALTERNATE BREATHING TUBES ALTERNATE FLOW CONTROL DEVICES ALTERNATE AIR SUPPLY HOSES ACCESSORIES CAUTIONS LIMITATIONS2 RT SERIES HOODS RT1 RT2 RT3 RT4 20BT RTBT HC24...

Page 3: ...irator Hood User Manual for use with supplied air respirators Respirator Hood Clamp BreathingTube Inner bib Clamp Flow Control Device Belt Air Supply Hose Fig 1 Clean Breathable Air Source Supplying Grade D or Higher Air Quality See Breath ing Air Requirements on page 4 Flow Control Device Without Climate Control Devices With Climate Control Devices Cold Only Hot Cold Adjustable Constant P A R T N...

Page 4: ...ains contaminant free Always use an inlet filter on your air source Use suitable after cooler dryers with filters and carbon monoxide monitors and alarms as necessary to assure clean breathable air at all times Compressed air should be regularly sampled to be sure that it meets Grade D requirements RT Series Respirator Breathing Air Pressure Air pressure should be monitored at the point of attachm...

Page 5: ...r F30 F30B F30S F31 F32 F33 F34 V10 25 50 75 150 200 250 300 1 2 3 5 5 14 15 15 18 19 29 25 34 31 39 F40 F40B F40S F41 F42 F43 F44 V10 25 50 75 150 200 250 300 1 2 3 5 5 22 25 24 27 27 37 33 40 38 45 V5 25 50 1 2 22 26 25 30 AC100030 AC100030B AC100030S AC100031 AC100032 AC100033 AC100034 V10 25 50 75 150 175 300 2 3 5 55 65 60 70 65 75 V5 25 50 1 1 55 65 56 69 DC5040 DC5040B DC5040S DC5041 DC5042...

Page 6: ...ngth This cannot be done for the 20BT breathing tube To do this first determine how much shorter you need to make the tube The tube cannot be shortened more than 6 inches Mark a line with a marker pen where you want to make the cut Take a sharp cutting instrument and cut through the breathing tube and foam inside Be careful not to damage the remaining tube or foam If this does occur replacement wi...

Page 7: ...r the top of the lens that allows the user to customize the curvature of the lens to his her personal preference This strap may be removed if desired 5 Make sure that the breathing tube is not twisted after donning 6 Tuck inner bib of hood into shirt or protective clothing for additional splash and overspray protection see Figure 9 7 Pull respirator outer bib over collar of shirt or protective clo...

Page 8: ...ce Cleaning Bullard does not recommend laundering the hood When the hood becomes dirty it should be discarded and replaced The respirator s plastic lens should be hand sponged with warm water and mild detergent rinsed and air dried After cleaning and before reassembling once again carefully inspect parts for signs of damage 8 Inspection Cleaning and Storage WARNING Failure to heed these instructio...

Page 9: ...ghtly to the hose so that no air can escape Make sure the hose has not been kinked or crushed by any equipment that may have rolled over it If any of the above signs are present or any other signs of excessive wear are detected replace the hose s immediately or remove the respirator from service Cleaning The air supply hose s should be hand sponged with warm water and mild detergent rinsed and air...

Page 10: ...available F35 Constant flow control valve with 1 2 Industrial Interchange Hansen compatible quick disconnect nipple Climate Control Assemblies for RT Series Airline Respirators For use with Breathing Air Compressors Cold Tubes Adjustable Flow AC100030 With 1 4 Industrial Interchange steel Hansen compatible quick disconnect nipple AC100031 With 1 4 Schrader steel quick disconnect nipple AC100032 Wi...

Page 11: ...5KF5032XXX 50 15 2 m with 1 4 Snap Tite steel fittings V5KF2533XXX 25 7 6m with 1 4 Snap Tite brass fittings V5KF5033XXX 50 15 2 m with 1 4 Snap Tite brass fittings V5KF2533XXXFF 25 7 6m with 1 4 Snap Tite brass fittings V5KF5033XXXFF 50 15 2 m with 1 4 Snap Tite brass fittings V5KF2533XXXFS 25 7 6m with 1 4 Snap Tite brass fittings V5KF5033XXXFS 50 15 2 m with 1 4 Snap Tite brass fittings V5KF253...

Page 12: ...ht collect basis 5 Returned products will be inspected upon return to the Bullard facility Bullard Customer Service will telephone you with a quote for required repair work which is not covered by warranty If the cost of repairs exceeds stated quote by more than 20 your Customer Service specialist will call you for authorization to complete repairs After repairs are completed and the goods have be...

Reviews: