3.3 Connecting pipes
In order to provide maximum exhaust gas efficiency for best
stove operations, the stove needs to be connected to the chimney
in the shortest and straightest possible manner. Additionally, this
connection should be able to be dismantled for cleaning and
inspection from time to time.
3.4 Fire protection distance to combustible components and the
furniture
3
There should be a minimum distance of 40 cm between Bullerjan
®
hot air stoves as well as the connecting pipes to the combustible
components and the furniture. In case of Bullerjan
®
hot air stoves
provided with a window, there should be a minimum distance of
80 cm between the front of the furnace and the combustible
components and the furniture. Combustible floor coverings have to
be protected by fireproof material. This material should be installed
at a distance of a least 50 cm to the front side and at least 30 cm to
the sides of the combustion
chamber door (O).
O
Distance to the combus-
tible components and the
furniture
Distance to fireproof
floor
3
The applicability of the above
mentioned values will be
subject to other rules and
requirements indicated in
the firing regulations and
building regulations of the
individual Federal States.
40 cm
40 cm
80 cm
50 cm
30 cm
30 cm
40 cm
32
Summary of Contents for 00
Page 3: ...Deutsch 3 Aufbauanleitung Seite 4 Benutzungsanleitung Seite 8 Aufstellhinweise Seite 15...
Page 8: ...8 2 Benutzungsanleitung...
Page 19: ...Typenschild Hologramm 19...
Page 20: ...1 7 10 8 6 3 9 4 5 International model 2 20...
Page 34: ...1 7 10 8 6 3 9 4 5 Mod le international 2 34...
Page 48: ...1 7 10 8 6 3 9 4 5 Modela internacional 2 48...
Page 62: ...1 7 10 8 6 3 9 4 5 Modello internazionale 2 62...
Page 76: ...76...