background image

Solutions of Fault

Phenomenon

Reason

How to Solve the problem

No power supply

1.   The   electric   leakage  switch

 

was

breaked off

2. The Fuse be break off

1. Check and eliminate the malfunction,

restart the spa

2. Please change fuse

No display on control

panel

1.   The   plug   which   connected   with   the

panel loose or disconnected

2. The Panel happened with malfunction

1. to   connect   the   plug   of   the   control

panel and the main box

2. Change a new control panel

LED light not work

1. Power of the light be break off
2. Fuse be break off
3. light be burn

1. To check if cable of the light is well

connected with main box or not

2. Change a fuse

3.

Change a new lampwick 

Ozone not work

1. Ozonater burn
2. Fuse be break off
3. Cable of the ozonater be cut off

1. Change a new ozonater
2. change a fuse
3. check if the cable of the main power

is connected  with  the  main  box  or
not.

Displaied “E1””FF” in

control panel

1.   temperature   detector   be   cut   off   or

shortcirculate 

2.   plug   of   the   temperature   detector   be

nundated by water

1. Connect the temperature detector
2.Change a new temperature detector

being incapable of

activate water pump,and

water pump icon

flashing

1.water not achieve the appointed level
2. water detector not connect well

1. To add more water to make it up to

the water detector

2. To   re-connect   the   line   of   water

detector

Heater not work, and

heating icon on panel

flashing

1. setting   water   temperature   lower   then

the water temperature

1. set the temperature degrees higher 

than the water  in tub 
temperature(between 15 and 43 °C

Leakage

1. silicon plaster not good 
2. PVC plaster not good
3. Blow out of the water pipe

1. To remove the jets then re-install one
2. To plaster once again

Change water pipe

12

Summary of Contents for SPA-562

Page 1: ...HOT TUB Model SPA 562 OPERATING INSTRUCTION 1...

Page 2: ...itch Volume down Open Spa Light On off MEM Radio channel Memory Lock Surfing pump 1 On off SET Radio channel read Close Surfing pump 2 On off Lasting Circulation Cleaning On off Surfing pump circulalt...

Page 3: ...eration Fig 3 Normal Temperature Display Fig 4 Senor on short circuit Display 1 When you first turn on the spa the backlight control panel is dim and LCD shows current time and temperature If spa happ...

Page 4: ...ation cleaning on Pre circulation cleaning Setting should be under the power off status just turn on the spa LCD will display 1 Press to start Circulation cleaning setting mode LCD showes and it is fl...

Page 5: ...ress to confirme all settings Notice The system will be exit automatically by pressing key of 1 Pre circulation setting be turn off 2 starting time of circulation 3 Lasting time of circulation 4 Finis...

Page 6: ...t the time It will be added 1 hour when pressing HOUR each time and hours could be added continually when pressing the HOUR without stopping The adjustment of hours is 00 23 It will be added 1 minute...

Page 7: ...2 Please note that it shows on or off on the LCD on means preheating is turned on mode when the time reaches your desired time heater will work If panel shows off means that heater not be set 3 Circu...

Page 8: ...works at the same The LCD shows the countdown time All the surfing pumps and blower will work for 30 seconds at every 30 minutes The Ozonier works at every 15 minutes The circulation cleaning will be...

Page 9: ...ill display Press the key MEM could memorize the present radio frequency Pressing the key MEM continually will memorize the present radio frequency in different channel The channel of max is 10 Name o...

Page 10: ...wer 16 Fahrenheit Celsius Temperature shift In the status of Power off pressing the key can change the mode of Fahrenheit Celsius degree 17 When there is no water in the spa All surfing pumps and heat...

Page 11: ...gh a residual current device RCD having a rated residual operating current not exceeding 30 mA The floor has to be capable of supporting the expected load An adequate drainage system has to be provide...

Page 12: ...a new ozonater 2 change a fuse 3 check if the cable of the main power is connected with the main box or not Displaied E1 FF in control panel 1 temperature detector be cut off or shortcirculate 2 plug...

Page 13: ...13...

Page 14: ...14...

Page 15: ...15...

Reviews: