background image

1

Max. with 6 KW heating system, pre-heating seting, water temperature displaying and setting 

2

Max. with 2 pcs surfing pumps,1 pc circultion pump, and one pc air blower.

3

Spa light and ozone setting

4

CD audio-input / Display of radio frequency,it can be preserved 10 channels

5

Volume display and 87 volume adjusting

6

Circulation cleaning/ time set circulation cleaning

7

24 hours display and setting

8

Memory preserve once power off

9

Fahrenheit & Celsius can be

 

mutually switched

10

Antifreezing functions

11

Keys with backlight

12

Lock settingl

13

Three-phase or single-phase available,can be choosed 110-120VAC or 220-240VAC 

14

Choice with offering a AC for circumscribing DVD or TV

15

Choice of power controlled

III

Operation

                

Fig.3:

Normal Temperature Display

            Fig.4

Senor on/short circuit Display

1

When  you   first  turn   on  the   spa,   the   backlight  control  panel  is  dim  and  LCD  shows  current   time   and

temperature. If spa happen with the short circuit the panel will display code

 “E1”

. When the radio frequency is

displayed “----” it indicates that the spa is in “power off” mode, and pre-heating and circulation cleaning function
are in off status.

2

Lock memory Mode

It is an optional function. Key board will be locked by pressing

 “

MEM

” 

once when panel is in off

mode

Pressing continuous twice of “

MEM

” to unlock the panel, the word 

LOCKED

will disappear.

3

Time Adjusting

In the status of “Power off

 and unworking of pre-heating and circulation cleaning. 

Pressing

  “

MIN

”or“

HOUR

  to   start  time  adjusting.   When  Minute   and   Hour   flashing,   you   can

adjust your desired time.

 It will be added one hour when pressing

 “

HOUR

 each time and the hours can be adjusted continually

3

Summary of Contents for SPA-562

Page 1: ...HOT TUB Model SPA 562 OPERATING INSTRUCTION 1...

Page 2: ...itch Volume down Open Spa Light On off MEM Radio channel Memory Lock Surfing pump 1 On off SET Radio channel read Close Surfing pump 2 On off Lasting Circulation Cleaning On off Surfing pump circulalt...

Page 3: ...eration Fig 3 Normal Temperature Display Fig 4 Senor on short circuit Display 1 When you first turn on the spa the backlight control panel is dim and LCD shows current time and temperature If spa happ...

Page 4: ...ation cleaning on Pre circulation cleaning Setting should be under the power off status just turn on the spa LCD will display 1 Press to start Circulation cleaning setting mode LCD showes and it is fl...

Page 5: ...ress to confirme all settings Notice The system will be exit automatically by pressing key of 1 Pre circulation setting be turn off 2 starting time of circulation 3 Lasting time of circulation 4 Finis...

Page 6: ...t the time It will be added 1 hour when pressing HOUR each time and hours could be added continually when pressing the HOUR without stopping The adjustment of hours is 00 23 It will be added 1 minute...

Page 7: ...2 Please note that it shows on or off on the LCD on means preheating is turned on mode when the time reaches your desired time heater will work If panel shows off means that heater not be set 3 Circu...

Page 8: ...works at the same The LCD shows the countdown time All the surfing pumps and blower will work for 30 seconds at every 30 minutes The Ozonier works at every 15 minutes The circulation cleaning will be...

Page 9: ...ill display Press the key MEM could memorize the present radio frequency Pressing the key MEM continually will memorize the present radio frequency in different channel The channel of max is 10 Name o...

Page 10: ...wer 16 Fahrenheit Celsius Temperature shift In the status of Power off pressing the key can change the mode of Fahrenheit Celsius degree 17 When there is no water in the spa All surfing pumps and heat...

Page 11: ...gh a residual current device RCD having a rated residual operating current not exceeding 30 mA The floor has to be capable of supporting the expected load An adequate drainage system has to be provide...

Page 12: ...a new ozonater 2 change a fuse 3 check if the cable of the main power is connected with the main box or not Displaied E1 FF in control panel 1 temperature detector be cut off or shortcirculate 2 plug...

Page 13: ...13...

Page 14: ...14...

Page 15: ...15...

Reviews: