MY21B01 - 12_1.0_09.07.2020
95
Documents
Inspection
Tests
Maintenance
Accept-
ance
Rejection
Light system
Rechargeable
battery
6 months
First examination
O.K.
Error message
Contact battery
manufacturer;
take out of
service
, new battery
Light cabling
6 months
Connections, correct
wiring
O.K.
Cable defective,
no light
New cabling
Rear light
6 months
Side light
Functional check
O.K.
No constant light
New rear light as specified in
parts list; replace if
necessary
Front light
6 months
Side light, daytime
riding light
Functional check
O.K.
No constant light
New front light as specified
in parts list; replace if
necessary
Reflectors
6 months
All complete, state,
fastening
O.K.
Damaged or not
all complete
New reflectors
Drive/gear shift
Chain/cassette/
pinion/
chainring
6 months
Check for damage
O.K.
Damage
Refasten if necessary or
replace as specified in parts
list
Chain guard/
spoke guard
6 months
Check for damage
O.K.
Damage
Replace as specified in parts
list
Bottom bracket
axle/crank
6 months
Check mount fastening
O.K.
Loose
Retighten screws
Pedals
6 months
Check mount fastening
O.K.
Loose
Retighten screws
Shifter
6 months
Check mount fastening Functional check
O.K.
Loose
Retighten screws
Shift cables
6 months
Check for damage
Functional check
O.K.
Loose or
defective
Adjust shift cables; new shift
cables if necessary
Front derailleur
6 months
Check for damage
Functional check
O.K.
Gear shift difficult
or not possible
Adjust
Rear derailleur
6 months
Check for damage
Functional check
O.K.
Gear shift difficult
or not possible
Adjust
Electric drive
Display
6 months
Check for damage
Functional check
O.K.
No screen,
defective screen
display
Restart, test battery, new
software, or new display –
take out of service
,
Electric drive
control panel
6 months
DriveCheck for
damage
Functional check
O.K.
No response
Restart; contact control
panel manufacturer, new
control panel
Tachometer
6 months
Speed measurement
O.K.
Pedelec
travelling 10%
too fast/slow
Take pedelec out of service
until the source of the error is
found
Cabling
6 months
Visual inspection
O.K.
Failure in
system, damage,
kinked cables
New cabling
Battery mount
6 months
Firmly in position, lock,
contacts
Functional check
O.K.
Loose; lock
doesn't close, no
contacts
New battery mount
Motor
6 months
Visual inspection and
mount
O.K.
Damage, loose
Refasten motor, contact
motor manufacturer, new
motor;
take out of service
Software
6 months
Check version
In latest
version
Not latest version Import update
Components
Frequency
Description
Criteria
Measures if rejected
Summary of Contents for 21-15-1016
Page 99: ...MY21B01 12_1 0_25 06 2020 99 Documents D Compact Charger A G A C EBE D F ...
Page 100: ...MY21B01 12_1 0_25 06 2020 100 Documents D EBE D F A G A C ...
Page 101: ...MY21B01 12_1 0_25 06 2020 101 Documents D A G A C EBE D F ...
Page 109: ...MY21B01 12_1 0_25 06 2020 109 Appendix II Declaration of conformity for incomplete machine ...
Page 110: ...MY21B01 12_1 0_25 06 2020 110 Appendix ...