DL500-Manuel-E
Page 5 / 20
DIN EN ISO 14121-1
Sicherheit von Maschinen - Risikobeurteilung - Teil 1: Leitsätze / Safety of machinery - Risk
assessment - Part 1: Principles
DIN EN ISO 12100-1
Sicherheit von Maschinen - Allgemeine Gestaltungsleitsätze, Risikobeurteilung und Risiko-
minderung / Safety of machinery - Basic concepts, risk assessment and risk reduction
DIN EN 55014-1 2012-05
Elektromagnetische Verträglichkeit, Anforderungen an Haushaltsgeräte, Elektrow-
erkzeuge und ähnliche Elektrogeräte, Teil 1: Störaussendung / Electromagnetic compatibility Requirements for
household appliances, electric tools and similar electrical appliances Part 1: Emission
DIN EN 55014-2-2009-06
Elektromagnetische Verträglichkeit - Anforderungen an Haushaltgeräte, Elektro-
werkzeuge und ähnliche Geräte - Teil 2: Störfestigkeit - / Electromagnetic compatibility - Requirements for
household appliances, electric tools and similar apparatus - Part 2: Immunity
Niederspannungsrichtlinie / Low Voltage Directive 2014/35/EG
Maschinenrichtlinie / Machinery Directive 2006/42/EG/37/EG
Windeck, 10.1.2016
Jürgen Bungard Geschäftsführer
Intended Use of Machine
Aqueous-alkaline or acid etching of printed circuit boards or plates.
Developing of positive or negative-working, aqueous-alkaline processable photoresists or laminates (add
defoamers if needed).
Alkaline resist stripping (additional filtration unit required).
All other applications require our written consent, or are performed completely on the operator's own risk.
Safety instructions
General
Please read the following instructions carefully and pay particular attention to information on operating
safety and set up.
Keep these instructions at a safe place. It contains information which also refer for later maintenance and
cleaning.
The machines are intended for chemical-physical treatment of printed circuit boards.
The machines are not designed to be embedded or interconnected with other machines or systems. They
may only be used in specially equipped rooms and be operated only by qualified staff. Children and pets
are to be kept away!
Transport
Only use suitable lifting and transport equipment such as forklifts or pallet lifts. Secure the machine
against sliding / tilting.
Place of installation
The machine must be standing level and around the machine there has to be sufficient space for opera-
tion and maintenance work (approx 1m on all sides). To prevent the penetration of chemicals into the
ground, set up the machine either in a room with solid, waterproof and chemical resistant floor (no tiles nor
concrete!) or in a chemical resistant waterproof collection tray which can take the whole filling volume
(safety tray available as an option).
Electricity
The machine is made from certified parts according to standard practice for electrical safety. This does
not relieve the user of his duty of care when handling electrically powered devices.
The I/O-labelled red main switch disconnects the machine from the power supply. We presuppose that the
safety fuses of the circuit and the residual current circuit are provided by the building's power supply.
Bungard Elektronik GmbH & Co. KG, Rilkestraße 1, 51570 Windeck – Germany
Tel.: +49 (0) 2292/5036, Fax: +49 (0) 2292/6175, E-mail: support@bungard.de