background image

Seite 4 / 6

 

7. Operation

The control panel (1) is protected by an upward 

tiltable,   transpar-

ent   cover   against 

contamination. 

The grasp to open 

the   cover   serves 

at   the   same   time 

to   start   and   stop 

the timer. 

7.1 Main Switch

The button on the 

upper   left   of   the 

control

 

panel 

switches the elec-

tric   circuit   for   the 

pump and the heating. 

7.2 Heating

The switch down right on the control panel con-

trols the heating. A thermostat regulates the tem-

perature on 2 degrees exactly. When the temper-

ature   reaches   the   preset   temperature   of   45°  C 

the lamp in the heating switch expires. As addi-

tional security against overheating the machine is 

equipped  with  a not  resetable  temperature  pro-

tection in the heater circuit. 

7.3 Timer

The   etching   time   is   controlled   by   digitally   ad-

justably and readable timer. You can set the timer 

from 1 second up to 9 minutes 59 seconds and 

operate it single handed. When the adjusted time 

expires an acoustic signal sounds. The timer  has 

an   LCD   display   and   three   buttons,   which   are 

marked with MODE, - and +. 

7.3.1 Adjusting the Etching Time 

Pressing the keys + and - the etching time can be 

preselected.   This   is   indicated   in   the   display.  A 

longer   pressure   on   one   of   the   keys   causes   a 

faster change. 

7.3.3 Start, Stop, Repetition 

Pressing the MODE key the etching procedure is 

started, the remaining time appears sequential in 

the display. The etching procedure is interrupted, 

if   you press the   MODE key. In both cases the 

procedure   can   be   continued   for   the   remaining 

time by   pressing the MODE key or closing the 

cover again. When the preset time runs out the 

etching pump stops. A buzzer sounds in several 

short intervals. The time stopped before is again 

indicated   by   pressing   once   MODE.   It   can   be 

changed now alternatively. After a second press 

of   MODE   the   machine   restarts.   Important!   The 

timer is protected tiltable transparent cover. You 

can start the machine indirectly by pressing the 

cover when you had set an etching time before. 

Nevertheless do not touch the timer with etching 

agent dirty gloves! 

7.4 Thermostat 

The reset knob for the thermostats is located in 

the case on the right and is preset on 45 degrees. 

Only if you use an etching agent, which requires 

compellingly

  another   temperature,   you   should 

adjust  this temperature. To do so  you must re-

move the housing (loosen the head screws at the 

front plate and in the back of the case, remove 

silicone from joint with a knife. Do not forget to 

seal the gab with silicone again). 

7.5 Board carrier

The boards are fixed on a carrier that has one 

fixed and one movable horizontal bar. To adjust 

the   setting   of   the   movable   bar,   just   loosen   the 

plastic screws and shift it into the desired direc-

tion.
Slide the carrier with the board(s) vertically into 

the   etching   compartment.   Lift   the   lid   towards 

yourself and drop it into a horizontal position.
The board carrier handle looks out of the etching 

compartment. To remove the carrier, just pull the 

handle upwards. The lid will open and slide back 

as far that you can remove the carrier. 

Jet 34d

Etching machine

Operating Instructions

(1)

Bungard Elektronik GmbH & Co. KG, Rilkestraße 1, 51570 Windeck – Germany

Tel.: +49 (0) 2292/5036, Fax: +49 (0) 2292/6175, E-mail: support@bungard.de

Summary of Contents for Jet 34d

Page 1: ... fotoresists or laminates if necessary add antifoaming agents 2 Technical Data Dimensions ca 60 x 110 x 85 cm Working height ca 90 cm Electrical connection 220 V 50Hz ca 1 5 kW Fill Quantity ca 16 l weight ca 35 kg Etching Speed ca 35µm Cu min fresh and warm etching liquid Motor 0 37Kw Max board di mensions 300 x 400mm Heating 1000 Watt Quarz glow bare 3 Safety Instructions The machines are intend...

Page 2: ...etching agent into the ground the machine must be installed a in a sufficiently large area with chemical firm waterproof ground lining no tiles no concrete or b in a chemical resistance waterproof collecting tray we offer this as option which seizes the entire volume of the etching li quid Exhaust air We recommend to install an exhaust above the machine for eventual etching steams This re commenda...

Page 3: ... the main switch and the switch for the heating While heating the heating switch is lit and the glow bare becomes an orange colour 8 Open the flap on top of the machine by pulling on the grasp of the plate holder The flap tilts back thereby and is locked Place the plate holder perpendicularly and close the flap 9 Set the timer as described later on and start the machine 10 If you open the flap wit...

Page 4: ...sing the MODE key or closing the cover again When the preset time runs out the etching pump stops A buzzer sounds in several short intervals The time stopped before is again indicated by pressing once MODE It can be changed now alternatively After a second press of MODE the machine restarts Important The timer is protected tiltable transparent cover You can start the machine indirectly by pressing...

Page 5: ... this time then the mud formation can be stopped and mud already set off will be brought back into solution 8 2 Cleaning of the machine in use of FeCl3 Equipment Apron eye protector Latex gloves 2 plastic scrapers 2 plastic sponges 2 buckets paper cleaning cloths plastic foil container from plastic for used etching agent Chemicals Hydrochloric acid HCl technically concentration approx 15 quantity ...

Page 6: ...equest we send an instruction on how to change this shaft ring 9 Guarantee All machines are submitted before distribution to examination on tightness function and continu ous operation firmness On the machine we grant a work warranty of 12 months to our customers starting from purchase date on accuracy in ma terial and processing We warrant at our choice by exchange of incorrect parts or by repair...