Page 8
CDBC ADJUSTMENTS & OPTIONAL SETTINGS
HIDDEN
SWITCH
HIDDEN
SWITCH
NOTE:
The following adjustments must be performed for each Brew Station.
Setting Brew Temperature
The brewer is factory set to brew at 200
°
F(95
°
C). To change this setting, press and hold the "HIDDEN" switch
beneath the "®". The word "TEMP" above the "ON/OFF" switch will glow to correspond with the temporary function
change of this switch. Repeatedly press and release the "ON/OFF" switch until one of the bank of temperature
indicators shows the approximate desired temperature. When two indicators are glowing, the temperature is
approximately the number between them.
Displaying Brew Temperature
The brewer is factory set with the temperature display disabled. To change this setting, press and hold the "ON/
OFF" switch and the "HIDDEN" switch beneath the "®" for five seconds, the entire bank of temperature indicators
will glow. Release both switches. Pressing and releasing the "ON/OFF" switch will toggle between turning the entire
bank of temperature indicators on-or-off, signifying the "ON" or "OFF" condition of this display. Wait for a few
seconds, the brewer will maintain this last setting.
Setting Brew Lockout
The brewer is factory set with the brew lockout disabled. Brew lockout prevents starting a brew cycle if the ready
indicator is not glowing. When an attempt at brewing cannot be allowed, the word "NOT" and "LOCKOUT" flash for
three seconds to indicate the reason the brew can't begin. To change the condition of the brew lockout, press and
hold the "HIDDEN" switch beneath the "®" and momentarily press the "BREW" switch.
Adjusting Automatic Warmer Shut-Off
The brewer is factory set with this feature disabled. The automatic warmer shut-off deenergizes all warmers
after a predetermined time period after the most recent brew cycle. To change the setting, press and hold the
"BREW" switch and the "HIDDEN" switch beneath the "®" for five seconds, the entire bank of temperature indicators
will flash on-and-off. Release both switches. Pressing and releasing the "BREW" switch will select the number of
temperature indicators from none to five. When no indicators are glowing, this feature is disabled and all warmers
will be controlled only by their respective switches. When one to five indicators are glowing, it indicates the
approximate number of hours of delay before all warmers will be automatically deenergized after the most recent
brew cycle.
IMPORTANT:
The tank
must
be full and refill solenoid shut off prior to making these adjustments.
Sprayhead must be installed while making these adjustments.
P1871
29319 030101