Summary of Contents for FMD DBC-3 4-CUP

Page 1: ...G SERVICE MANUAL ADDENDUM BUNN O MATIC CORPORATION OF CANADA LTD 280 INDUSTRIAL PARKWAY SOUTH AURORA ONTARIO L4G 3T9 PHONE 905 841 2866 FAX 905 841 2775 29215 7002 5 02 1998 Bunn O Matic Corporation FMD DBC 3 4 CUP ...

Page 2: ... The mixing chamber must drain at the end of each dispense The dispense times can be individually programmed by following the procedures described in Programming Modes PROGRAMMING MODES 1 Enter Exit a To enter the program mode simultaneously press and hold the M and L switches for 5 seconds on the position to be programmed The L E D will flash indicating the program mode b To exit the program mode...

Page 3: ...solid indicating the task is complete The program mode is exited when the Stop switch is released 5 Running Hopper Throw Test The hopper throw can be checked by automatically running the hopper motor as follows a Remove the steam collector and mixing chamber from under the hopper to be checked b Position a small cup under the hopper outlet c Enter the program mode on the position you want to check...

Page 4: ...itches on any one of the positions for 10 seconds All 3 position L E D s will begin flashing indicating that the dispenser is ready to accept a new password Then just wait 5 seconds without pressing the Stop switch NOTE There will be no indication when the 5 seconds are up and the password is reset to 0 RE INITIALIZE TO FACTORY DEFAULTS This resets all dispense time settings and hopper throw rates...