background image

9

RE-INITIALIZE TO FACTORY DEFAULTS

This resets all dispense time settings and hopper throw rates to the factory defaults, and resets the password 

to 0 (no password.)

1.   Disconnect the dispenser from the power source.

2.   Place the Rinse/Run switch in the “Run” position.

3.   Press and hold the left small, center small, and the Stop switches at the same time.

4.   While holding the switches, connect the dispenser to the power source (this is intended to be difficult.) The 

switches must be held for about 5 seconds. When the task is completed, the left, center and right L.E.D.’s 

flash until the switches are released.

5.   Wait an additional 10 seconds before operating the dispenser.

COLD BEVERAGE SET-UP  (OPTIONAL)

Cold beverages may be dispensed from the left dispense position.  Simply place the HOT/COLD switch near the 

left whipper chamber in the “COLD” (upper) position.

ADJUSTMENTS

The hot or cold beverage solenoids  are preset to dispense approximately 

9

/

10 

ounce per second.  This amount 

can be adjusted:

1.  Disconnect the dispenser from the power source.

2.  Remove the small left side access panel.

3.   Rotate the control at the base of the desired solenoid(s) clockwise to decrease or counterclockwise to increase 

the amount of water.

4.  For cold beverage adjustment remove the 1-1/2” plug on the lower left side of the dispenser and rotate the 

needle valve clockwise to decrease or counterclockwise to increase the amount of cold water.

DRAINING THE HOT WATER TANK

CAUTION - The dispenser must be disconnected from the power source throughout these steps

1.  Disconnect the dispenser from the power source.

2.  Open front door and place tank heater switch in the “OFF” (upper) position.

3.  Shut off and disconnect the incoming water supply. 

4.  Remove the top panel.

5.  Gently remove one of the grommets from the tank lid.

6.  Insert a tube to the bottom of the tank and syphon ALL of the water out.

 

NOTE - The dispenser must be refilled using the INITIAL FILL & HEAT steps before reconnecting to the power

source.

29215 011510

PREVENTIVE MAINTENANCE

Bunn-O-Matic

®

 Corporation recommends that preventive maintenance be performed at regular intervals. Maintenance 

should  be  performed  by  a  qualified  service  technician.  For  Technical  Service,  contact  Bunn-O-Matic

®

  Corporation  at 

1-800-286-6070.

NOTE: Replacement parts or service caused by failure to perform required maintenance is not covered by warranty.

Cycle

(months)

6

6

3 or as

needed

Item 

 

 

 

Part Number

Mixing Chamber Kit 

 

32906.0000

Whipper Motor Seal Kit 

 

29128.0000

Whipper Shaft Seal Kit 

 

26356.1000

Summary of Contents for FMD DBC-3

Page 1: ... have the latest revision of the Operating Manual or to view the Illustrated Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at www bunn com This is absolutely FREE and the quickest way to obtain the latest catalog and manual updates For Technical Service contact Bunn O Matic Corporation at 1 800 286 6070 29215 0000J 05 11 1998 Bunn O Matic Corporation ...

Page 2: ... sole discretion that the equipment does not conform to the warranty BUNN at its exclusive option while the equipment is under warranty shall either 1 provide at no charge replacement parts and or labor during the applicable parts and labor warranty periods specified above to repair the defective components provided that this repair is done by a BUNN Authorized Service Representative or 2 shall re...

Page 3: ...SING THIS PRODUCT THIS APPLIANCE IS HEATED WHENEVER CONNECTED TO A POWER SOURCE 00831 0000F 3 98 1998 BUNN O MATIC CORPORATION USER NOTICES Carefully read and follow all notices on the equipment and in this manual They were written for your protection All notices are to be kept in good condition Replace any unreadable or damaged labels 37881 0000 00656 0001 As directed in the International Plumbin...

Page 4: ...l source 3 Open the front door of the dispenser and place the heater switch in the OFF upper position 4 Connect the dispenser to the power source 5 If plumbing is to be hooked up later be sure the dispenser is disconnected from the power source If plumb ing has been hooked up the dispenser is ready for Initial Fill Heat CE REQUIREMENTS This appliance must be installed in locations where it can be ...

Page 5: ... the front door and place the heater switch in the ON lower position A tank full of cold water will take approximately forty minutes for the water to heat on 120 volt versions and twenty minutes on 120 240 240 and 230 volt versions During this waiting period complete these dispenser set up steps a Place a set of keyholes in the splash panel over the screws beneath the hopper access door and push d...

Page 6: ...onal 4 hours 12 hours total a rinse cycle has still not been run all three position L E D s will light continuously and the hopper drives will be disabled until a rinse sequence has been run RUNNING A RINSE SEQUENCE 1 Place the Rinse Run switch in the rinse position 2 Sequentially or simultaneously at each of the three positions press any of the three dispense switches The dispenser will run for 1...

Page 7: ...ery short timed dispense d Repeat for remaining cup sizes if desired e Exit the programming mode see step 1 b 3 Increasing Decreasing the Hopper Dispense Rate a Enter the program mode on the position you want to program see step 1 a b Place the Rinse Run switch in the Rinse position c Press and hold down on the stop switch and press the small switch to decrease the dispense rate or press the large...

Page 8: ...ory to 0 no password a To enter the password programming press and hold any two dispense size switches on any one of the posi tions for 10 seconds All 3 position L E D s will begin flashing indicating that the dispenser is ready to accept a new password b When the switches are released the 3 L E D s will stop flashing At this time press the Stop switch the num ber of times that is the password For...

Page 9: ...ecrease or counterclockwise to increase the amount of water 4 For cold beverage adjustment remove the 1 1 2 plug on the lower left side of the dispenser and rotate the needle valve clockwise to decrease or counterclockwise to increase the amount of cold water DRAINING THE HOT WATER TANK CAUTION The dispenser must be disconnected from the power source throughout these steps 1 Disconnect the dispens...

Page 10: ...a deberá realizarse diariamente 1 x 7d 1 2 3 4 5 a Wash b Rinse c Sanitize d Dry a Lave b Enjuague c Desinfecte d Seque 7 8 6 a b c 9 7 Replace Light Bulbs as required 1 Para limpiar las camaras de mezcla coloque el interruptor en la posicón ENJUAGUE MARCHA RINSE RUN y pulse el boton para espumar y distribuir la bebida DISPENSE 2 Gire el codo hacia arriba remueva las tolvas llene las tolvas con pr...