WATER & POWDER CALIBRATION
NOTE: You will need a gram scale and containers to catch powder and water.
1. Fill hoppers.
2. Rinse all heads prior to calibration.
3. Lift door, place switch in Program position.
4. Press HOT WATER button button until “Calibra-
tion” screen. Press “Yes”.
CALIBRATION ?
EXIT YES
CAL WATER 1 ?
PRESS DISPENSE
ENTER VOLUME 1
(-) 11.0 oz
(+)
CAL POWDER 1 ?
PRESS DISPENSE
5. Press HOT WATER button until “Cal Water X?”
(where X is head to be calibrated)
6. Place container under dispense head being tested.
Then press and release membrane dispense but-
ton for the dispense head being tested.
7. The unit will automatically dispense for ten sec-
onds.
8. Press HOT WATER button, the screen should
change to “Enter Volume” Enter the volume of
water captured in graduated cylinder (in ounces).
(Use a 5 run average)
9. Press HOT WATER button, the next screen should
be “Cal Powder X?” (where X is head to be cali-
brated)