40
SERVICE (cont.)
If voltage is present as described the transformer is
operating properly.
If voltage is not present as described, replace the
transformer.
Removal and Replacement:
1. Loosen the two #8-32 screws securing the com-
ponent bracket to the dispenser housing base.
2. Pull component bracket out the front of the dispenser
far enough so the transformer connector can be
disconnected from the main wiring harness.
3 Disconnect the transformer four pin connector from
the four pin plug on the main wiring harness.
4. Remove the two #6-32 keps nuts securing the trans-
former to the rear of the component bracket.
5. Remove and discard the transformer.
6. Install new transformer on the rear of the component
bracket and secure with two #6-32 keps nuts.
7. Connect the four pin connector on the transformer
to four pin plug on the main wiring harness.
8. Place the component bracket into position and
tighten the two #8-32 screws.
WHI/BLK - T12
WHI/GRN - T8
WHI - 120V T2, 240V T6
BLK - TI
FIG. 49 TRANSFORMER TERMINALS
P1647
TRANSFORMER
FIG. 48 TRANSFORMER
Location:
The transformer is mounted on the side of the tank
mounting bracket for models 3,4 & 5. The transformer
is located behind the lower front access cover, mounted
on the rear side of the component bracket for models
3S,3S+,5S & 5S+.
Test Procedure:
1. Disconnect the dispenser from the power source.
2. Disconnect the four pin plug from the main harness
from the four pin connector on the transformer.
3 Check the voltage across black wire pin 1 and the
white wire pin 2 on the plug from the main har-
ness. Connect the dispenser to power source. The
indication must be:
a) 120 volts ac for two wire 120 volt models, three
wire 120/208 volt and three wire 120/240 volt
models.
b) 240 volts ac for two wire 240 volt models.
c) 230 volts ac for two wire 230 volt models.
4. Disconnect the dispenser from the power source.
If voltage is present as described reconnect the plug
and the connector and proceed to #5.
If voltage is not present as described, refer to the
Wiring
Diagrams
and check the main wiring harness.
5. Check the voltage between J3-5 and J3-6 on the
six pin connector at the control board. Connect the
dispenser to the power source. The indication must
be 24 volts ac.
P3250.25
42032 060109
Summary of Contents for IMIX
Page 10: ...10 42032 060109 NOTES ...
Page 46: ...46 42032 060109 ...
Page 48: ...48 42032 060109 ...