7
TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE
REMEDY
Water is not hot
Spitting or excessive steaming
Dripping from dispense tip
Water flows into tank continuously
Product overflows mixing chamber
1. Limit thermostat
2. Control thermostat
3. Triac
4. Tank heater
1. Lime build up
2. Control thermostat
1. Lime build up
2. Dispense Solenoid Valve
1. Level probe
2. Solenoid valve (inlet)
3. Control board
1. Dispense tip
2. Dispense solenoid valve
3. Vacuum fan
Disconnect power and disconnect limit thermo-
stat from wiring harness and test for continuity
(A) Check tank temperature setting in Program-
ming menu
(B) Check temperature probe function and cali-
bration, see “CAL tank temp” under “CALIBRA-
TION ?” menu
Test triac, use “TANK HEATER ?” under “DIAG-
NOSTICS ?” menu
Disconnect wire leads from tank heater, check
for continuity across tank heater leads.
Inspect tank assembly for excessive lime depos-
its. Delime as required.
(A) Check tank temperature setting in Program-
ming menu
(B) Check temperature probe function and cali-
bration, see “CAL tank temp” under “CALIBRA-
TION ?” menu
Inspect tank assembly for excessive lime depos-
its. Delime as required.
Remove the dispense solenoid valve and clear
any obstructions. Rebuild or replace valve as
necessary.
Check for lime buildup on level probe. Clean as
required.
Test inlet solenoid valve, see “TEST REFIL ?” un-
der “DIAGNOSTIC ?” menu
Test inlet solenoid valve circuit, see “TEST REFIL
?” under “DIAGNOSTIC ?” menu
Check dispense tip for obstructions.
Check valve flow rate.
Check vacuum fan operation.