Page 25
NOTE: If the display is already on the DILUTION CAL
screen, skip steps 2-3 and proceed directly to step 4.
2. Press and hold the right hidden switch until the
display reads SET LANGUAGE. Press and release
the right hidden switch until the display reads
CALIBRATE FLOW?
3. Select YES to advance to SPRAY HEAD CAL screen.
Select NO to advance to DILUTION CAL.
4. Select YES.
The display should read CONTAINER READY? If
container is under the funnel, select YES.
5. The display should read CALIBRATE DILUTE. Select
START to begin the dilution flow for calibration. The
display should read CALIBRATE DILUTE...60 SEC
TO FINISH. The 60-second timer on the display will
count down to zero. When the counter reaches zero,
the display will change to DILUTE OZ/M, along with
a number.
6. Measure the amount of water in the container and
using the (-) and (+), adjust the amount on the
display to match the amount in the container. Then
select DONE.
7. The display should now read NEW DILUTE FLOW,
along with the correct flow rate of the sprayhead.
After about 5 seconds, the display will return to the
CALIBRATE FLOW screen. To exit programming and
return to the MAIN SCREEN, press ENABLE BREW
ON/OFF switch.
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
PROGRAMMING THE BREWER (cont.)
41581.2 091609
NOTE: On dual dilution models, left and right dilution
calibrations will be shown.