5
ELECTRICAL REQUIREMENTS
CAUTION:
The dispenser must remain disconnected from the power source until specified in Electrical Hook-
Up.
The LCA-2 IC dispenser is supplied with a 120-volt / 15 Amp cord set and requires a 2-wire, grounded,
individual branch circuit rated for 120 volts AC, 15 amp, single phase, 60Hz. The mating connector must be
a NEMA 5-15R.
PLUMBING REQUIREMENTS
The dispenser may be connected to a cold water system with operating pressure between 20 and 90 psi (138 and
620 kPa) from a 1/2” or larger supply line. A shut-off valve should be installed in the line before the dispenser.
Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa). The
water inlet fitting is 3/8” flare. Dispensers set up to deliver to 1.8 Oz./sec. (53.2 ml/sec) per dispense tip, require
a water supply source that can deliver a minimum of 1.7 gpm (6.4 lpm) at the inlet fitting.
NOTE: Bunn-O-Matic recommends 3/8” tubing from the 1/2” water supply line. At least 18 inches of FDA approved
flexible beverage tubing, such as reinforced braided polyethylene or silicone, before the dispenser will facilitate
movement to clean the counter top. It can be purchased direct from Bunn-O-Matic (part number 00326.0000).
Bunn-O-Matic does not recommend the use of a saddle valve to install the dispenser. The size and shape of the
hole made in the supply line by this type of device may restrict water flow.
38059 060611
NOTE
- Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed
and maintained in accordance with federal, state and local codes.
As directed in the International Plumbing Code of the International Code Council and the Food Code
Manual of the Food and Drug Administration (FDA), this equipment must be installed with adequate
backflow prevention to comply with federal, state and local codes. For models installed outside the
U.S.A., you must comply with the applicable Plumbing /Sanitation Code for your area.