17
36026 120105
MENU SCREEN
ACTION
DESCRIPTION
CAL LEFT PUMP ?
PULL DISPENSE
CAL LF PUMP VOL
(-) 43mL (+)
CAL LF WTR FLOW ?
PULL DISPENSER
CAL LF WTR VOL
(-) 36.0OZ (+)
CAL LEFT SIDE ?
EXIT YES
CAL RIGHT SIDE ?
EXIT YES
If NO - go to CAL RIGHT SIDE menu.
CAL LEFT SIDE ?
EXIT YES
The following functions are for diagnostic and troubleshooting purposes and typically do not have to be
adjusted. Contact your local service agent for assistance before making changes to these functions.
RINSE TIME ?
(-) 12 Hrs (+)
RINSE LOCKOUT ?
NO EXIT YES
BIB EMPTY LOCKOUT
NO EXIT YES
BREW LOCKOUT ?
NO EXIT YES
DLY REPEAT DISP
(-) 0 SEC (+)
Place a 50 mL (#34843.1000)
graduated cylinder under the
Left dispense tip, then activate
the Left Dispenser
Use the (+) or (-) buttons to
enter volume collected
Place a 64 Oz. (2000 mL)
container under the Left
dispense tip, then activate the
Left Dispenser
Use the (+) or (-) buttons to
enter volume collected
NONE
Select (YES) to enable
Calibration routine.
Select (YES) to enable
Use the (+) or (-) buttons to
adjust Rinse Alarm delay
Select (YES) to enable
Select (YES) to enable
Select (YES) to enable
Use the (+) or (-) buttons to
adjust the Delay Time
The Left Pump will dispense concentrate for 20
seconds, then shut off automatically. Collect and
measure the concentrate dispensed.
Enter the volume of concentrate measured from
the Left Pump in mL, (not Oz.) regardless of
Preferred Units selected.
The Left Dispenser will dispense hot water for 20
seconds, then shut off automatically. Collect and
measure the water dispensed.
Enter the volume of the water measured from the
Left dispenser in Oz. (mL).
Scroll down to bypass this screen.
Selecting Yes will enable the Right Dispenser
Calibration routine, (see Pump Calibration) prior
to calibrating the dispenser.
Selecting Yes will enable the Left Dispenser
Calibration routine, (see Field Calibration before
attempting to calibrate the dispenser).
Enter the desired time between required Rinse
Cycles in hours, [8 - 24 hrs.]
Select YES to Lockout dispensing until the Rinse
Alarm has been cleared. Default is NO
Select YES to Lockout dispensing until the
Concentrate BIB has been replaced. Default is
NO
Select YES to Lockout dispensing until the hot
water tank is at READY Temp. Default is NO
Enter the desired time delay before allowing the
next dispense to take place, [0 - 10 sec.]
Summary of Contents for LCR-2