Page 16
PROGRAMMING
CALIBRATE TANK TEMPERATURE
200.0
1.0
199.0
200.0
Insert a known acurate temperature sensing probe/device through the tank lid plug
to a depth of 6 inches. Enter the "Measured temperature" in the white box. The
"Un-calibrated Temperature" should be the old reading. "Calibrated Temperature"
should be equal to the measured temperature. "Temperature Offset" should be
the difference between the two.
CALIBRATE REFILL SENSITIVITY
825
520
Filled
Adjust sensitivity of refill probe according to water quality.
Always make
sure that the "Status" is filled. "New Refill Value should always be
higher than "Current Refill Value" when water is contacting the
tank refill probe.
DIAGNOSTICS
These two screens allows you to manually operate various machine components
for testing purposes. All are defaulted to Off" and may be momentarily turned on
by pressing the associated white box next to it.
49251.0 062014
SERVICE TOOLS:
FOR TRAINED TECHNICIANS ONLY!