PROGRAMMING

49063.2 032014

Setting the Large and Small Brew volume:

1.  Press and hold the Large (to adjust Large brew)or Small brew switch (to adjust Small) for 5 seconds 

while 

the brew chamber is open

. During that time the red/green LEDs will fl ash rapidly. After 5 seconds the leds 

will turn off.

The large batch switch will increase the volume and the small batch switch will decrease the volume.

2.  If setting the large batch, each time the large or small switch is pressed, the red led will momentarily fl ash.

3.  If setting the small batch, each time the large or small switch is pressed the green led will momentarily fl ash.

4.  Each time the switch is pressed, the volume is increased or decreased by .25 Ounces.

If the maximum volume (16.0) or the minimum volume (4.0) is reached, the red LED will fl ash rapidly for the 
large volume. The green LED will fl ash rapidly for the small volume. 

DEFAULTS: 8oz/6oz

If no switches are depressed for 10 seconds -- the setup mode is exited

Changing the temperature set point between high altitude (190° F) and low altitude (200° F)  (default = 200° F):

1.  Press the Large brew switch 5 times (within 5 seconds) with the brew chamber open. This will cause the 

temperature to toggle modes. If the New temperature is 190 degrees, the red LED will fl ash 5 times. If the 
New temperature is 200 degrees, the red LED will fl ash 10 times.

Enabling or Disabling the Energy save mode:

1.  Press the Small brew switch 5 times (within 5 seconds) with the brew chamber open. This will cause the 

energy save to toggle modes. If the new mode is energy save enabled, the green Led will fl ash 5 times. If the 
new mode is energy save disabled, the green Led will fl ash 10 times.

Restoring the factory defaults:

1.  Turn off the main power switch. 
2.  Press and hold both Large and Small batch Switches and turn on power switch. Continue pressing both 

switches for 5 seconds. 

3.  After 5 seconds, the red and green LEDs will fl ash rapidly for 5 seconds, the operator must release and 

press both the Large and Small Batch switches within 5 seconds. The red and green LEDs will turn off for 
approximately 5 seconds and then turn on and off 5 times indicating success.

Summary of Contents for My Cafe MCR

Page 1: ... of the Operating Manual or to view the Illustrated Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at www bunn com This is absolutely FREE and the quickest way to obtain the latest catalog and manual updates For Technical Service contact Bunn O Matic Corporation at 1 800 286 6070 49063 0002A 04 14 2014 Bunn O Matic Corporation My Café MCR ...

Page 2: ...tatements by such individuals whether oral or written do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that the equipment does not conform to the warranty BUNN at its exclusive op tion while the equipment is under warranty shall either 1 provide at no charge replacement parts and or labor during the applicable parts and labor warranty periods spe...

Page 3: ...ice personnel only Disconnect power before servicing WARNING s 4 6 2 2 5 4 s 7 93 42 9 2 5 4 33 3 s 4 2 0 5 2 2 s 7 4 42 3 s 0 534 3 7 9 52 4 0 9 2 3 3 15 0 4 2 2 3 2 READ THE ENTIRE OPERATING MANUAL BEFORE USING THIS PRODUCT 00986 0002F 10 07 1994 Bunn O Matic Corporation As directed in the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug...

Page 4: ...perature is between 5 C to 35 C Appliance shall not be tilted more than 10 for safe operation An electrician must provide electrical service as specified in conformance with all local and national codes This appliance must not be cleaned by water jet This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and k...

Page 5: ...e use of a saddle valve to install the brewer The size and shape of the hole made in the supply line by this type of device may restrict water flow As directed in the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Administration FDA this equipment must be installed with adequate backflow pre vention to comply with federal state and local...

Page 6: ...ter to the max fill line PRESS LARGE BREW BUTTON Water will flow into the cup Whenfinished discardcontents of cup OPEN CLOSE CHAMBER Pull bottom or push top of handle to open When heated green light open then close brew chamber PLACE CUP Place a large empty cup 10 oz or more under the brew chamber CONNECT TO POWER SOURCE Turn on main power switch Water will flow from reservoir to fill the internal...

Page 7: ... brew button Once the brew cycle is finished remove cup BREWING 49063 2 032014 INSERT CUP Push lid down to close brew chamber PLACE CUP Placeemptycupunderthebrew chamber REMOVE TOP COVER Pour in water up to fill line POUR IN MODELS ONLY NOTE Light will change from green to alternating red green during brew cycle ...

Page 8: ...er back into housing CLEANING Theuseofadampclothrinsedinanymild nonabra sive liquid detergent is recommended for cleaning all surfaces on Bunn O Matic equipment DRIPTRAY 1 Lift the driptray cover straight up 2 Pull the driptray out and clean as needed 49063 2 032014 SCREEN 1 Disconnect brewer from power source 2 Remove reservoir cover 3 Pullscreenassemblyupbyeitherofthetwotabs 4 Wash and rinse as ...

Page 9: ...ol before proceeding 2 Remove the top cover 3 Lift reservoir up and set aside 49063 2 032014 4 Remove 5 screws securing rear cover 5 Remove cover 6 Place brewer next to a sink 7 Remove small tube from left side of tank lid 8 Insertasyphontubeorhosethroughthegrommet hole to syphon water out of tank ...

Page 10: ...ed Changing the temperature set point between high altitude 190 F and low altitude 200 F default 200 F 1 Press the Large brew switch 5 times within 5 seconds with the brew chamber open This will cause the temperature to toggle modes If the New temperature is 190 degrees the red LED will flash 5 times If the New temperature is 200 degrees the red LED will flash 10 times Enabling or Disabling the En...

Reviews: