Page 9
TROUBLESHOOTING (cont.)
Problem
Brew cycle will not start. (cont.)
Water flows into tank continuously
(On/Off brew station warmer switch
“OFF”).
Water flows into tank continuously
(On/Off brew station warmer switch
“ON”).
Water is not hot.
Decanter warmer is not hot.
Probable Cause
4. On/Off Brew Station Warmer
Switch
5. Start Switch
6. Brew Timer
7. Solenoid Valve
1. Solenoid Valve
1. Brew Timer
1. Limit Thermostat
CAUTION
Do not eliminate or bypass limit
thermostat. Use only B.O.M. replace-
ment part
#29329.1000
2. Control Thermostat
3. Tank Heater
1. Warmer Switches
2. Decanter Warmers
Remedy
Refer to Service - On/Off Brew
Station Warmer Switch for testing
procedures. See page 18.
Refer to Service - Start Switch for
testing procedures. See page 23.
Refer to Service - Timer for testing
procedures. See page 13 & 14.
Refer to Service - Solenoid Valve for
testing procedures. See page 22.
Refer to Service - Solenoid Valve for
testing procedures. See page 22.
Refer to Service - Timer for testing
procedures. See page 13 & 14.
Refer to Service - Limit Thermostat
for testing procedures. See page
21.
Refer to Service - Control Thermo-
stat for testing procedures. See
page 16.
Refer to Service - Tank Heater for
testing procedures. See page 24.
(A) The Warmer Switch(es) must be
in the “ON” position for the warmer
to operate.
(B) Refer to Service - Warmer
Switch(es) for testing procedures.
See pages 18 & 19.
Refer to Service - Warmers for test-
ing procedures. See page 17.
32440 070700
Part II
Summary of Contents for OL
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 27: ...Part I ...
Page 48: ... BUNN HOUSINGS PANELS ModelOL OL RL OT RT _ b _ _ 16 15 14 RevisedDecemberl999 Part I ...
Page 50: ... BUNN HOUSlNGS PANELS ModelRL D I a OL RL OT RT 2 P1649 6 RevisedDecember1999 Part I ...
Page 54: ... BUNN HOUSlNGS PANELS ModelRT OL RL OT RT P1651 IO RevisedDecember1999 Part I ...
Page 60: ...BUNN TANK COMPONENTS ModelsOT RT OL RL OT RT P1653 16 RevisedDecemberl999 Part I ...
Page 62: ...BUNN STRAlNER ModelsOL RL OL RL OT RT 9 8 IO 7 P1654 18 RevisedDecember1999 Part I ...
Page 68: ...BUNN WARMER ASSEMBLIES ModelsOL OT OL RL OT RT P1657 24 RevisedDecember1999 Part I ...
Page 72: ......
Page 73: ......
Page 76: ...ELECTRICAL OPERATING CONTROLS ModelRL OL RL OT RT 32 RevisedDecember1999 Part I ...
Page 78: ...Part I ...
Page 82: ...Part I ...
Page 86: ...BUNN 8 FUNNELS BASKETS OL RL OT RT 47 RevisedDecember1999 Part I ...
Page 90: ......
Page 92: ......
Page 170: ...44 BUNN OL RL OT RT FUNNELS BASKETS P1663 1 2 3 6 4 5 7 9 6 7 1 8 10785 010708 Part II ...
Page 174: ......