3
00656.0000
00986.0000
USER NOTICES
Carefully read and follow all notices on the equipment and in this manual. They were written for your protection.
All notices are to be kept in good condition. Replace any unreadable or damaged labels.
29793 011500
10. Slowly feed the door support arms through the slots located on the front of the Powder Auto-Fill.
11. Continue to slowly feed the door support arms through the slots until the magnet strikes on the back of the
door engage the magnets on the Powder Auto-Fill.
12. Locate the #8-32 x .375" truss head screws and brass spacers set aside earlier.
13. Place one brass spacer on each screw.
14. Insert one screw/spacer assembly through the door hinge, locating the spacer inside the hinge bushing and
threading the screw into the hinge mount on the Powder Auto-Fill cover. Repeat for other side.
15. Install PAF level probe (BOM #29728.1000) by sliding it into the notched area at the top rear of the CDS hopper.
The probe should be firmly seated in the notch and touching the contact pin protruding from the front of the
CDS cooling drum mount.
NOTE: At this point, it is important that the CDS machine is fully assembled according to the instructions outlined
in the CDS Operating and Service Manual.
16. Place the assembled Powder Auto-Fill on top of a hopper of a fully assembled CDS machine, taking care to align
the Powder Auto-Fill guide rails over the rollers on the CDS.
17. Connect the Powder Auto-Fill power cord to the outlet located on the CDS auger motor cover.
18. Attach a flexible water line to the .25" flare fitting on the back panel of the Powder Auto-Fill.
NOTE: A water strainer assembly (BUNN-O-MATIC #23820.1000) should be installed in line prior to the flexible
water line.