Page 10
TROUBLESHOOTING (cont.)
PROBLEM
Dripping from sprayhead
Water flows into tank continuously
(ON/OFF Switch "ON")
Water flows into tank continuously
(ON/OFF Switch "OFF")
Beverage overflows dispenser
PROBABLE CAUSE
1. Syphon system
2. Lime build-up
CAUTION -
Tank and tank compo-
nents should be delimed regularly
depending on local water condi-
tions. Excessive mineral build-up
on stainless steel surfaces can ini-
tiate corrosive reactions resulting
in serious leaks.
3. Solenoid valve (ST, STF, STA &
STFA)
1. Timer (ST, STF, STA & STFA)
2. Start switch
3. Liquid level board
4. Relay
1. Solenoid valve (ST, STF, STA &
STFA)
1. Dispenser
2. Timer (ST, STF, STA & STFA)
REMEDY
The brewer must be level or slightly
lower in front to syphon properly.
Inspect the tank assembly for ex-
cessive lime deposits. Delime as
required.
Remove the solenoid valve and
clear any obstructions. Rebuild or
replace the valve if necessary.
See page 18
Refer to
Service - Timer for testing
procedures. See page 22 or 24
Refer to
Service - Start Switch for
testing procedures. See page 19
Refer to
Service - LiquidLevel
Board for testing procedures. See
page 26
Refer to
Service - Relay for testing
procedures. See page 28
Remove the Solenoid Valve and
clean any obstruction. Rebuild or
replace the valve if necessary. See
page 18
The dispenser must be completely
empty before starting a brew cycle.
Refer to
Service - Timer for testing
procedures. See page 22 or 24
29251 052500
Summary of Contents for S
Page 31: ...Page 31 29251 052500 ...
Page 32: ...Page 32 29251 052500 ...
Page 33: ...Page 33 29251 052500 ...
Page 34: ...Page 34 29251 052500 ...
Page 35: ...Page 35 29251 052500 ...
Page 36: ...Page 36 29251 052500 ...
Page 37: ...Page 37 29251 052500 ...
Page 38: ...Page 38 29251 052500 ...
Page 39: ...Page 39 29251 052500 ...
Page 40: ...Page 40 29251 052500 ...
Page 41: ...Page 41 29251 052500 ...
Page 42: ...Page 42 29251 080400 ...
Page 43: ...Page 43 29251 052500 ...
Page 44: ......