Page 35
FACTORY DEFAULTS
This function allows the operator to erase
all
of the
previously entered recipes and ad messages. Factory-
set default values will replace
all
previous settings.
Procedure to set factory defaults:
1. Press and hold the ® pad until
SET NEW RECIPES
appears. Release the ® pad. Press and release ®
until the display reads
FACTORY DEFAULTS
.
2. Pressing
NO
in this screen will revert to the
MAIN
SCREEN
. Press
YES
to replace the defaults. This
advances to
WILL REPLACE ALL BREWING SET-
TINGS
. This screen will alternate with
ARE YOU
SURE?
.
3. Pressing
NO
in the confirmation screen will revert
to
MAIN SCREEN
, without resetting the brewing
setups to the defaults. Press
YES
to load the
defaults. This will then revert to the
MAIN SCREEN
,
and the factory default values will replace
all
previously entered values. It will NOT reset the
summation Brew counter.
P2312
29877 121302
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
FACTORY DEFAULT VALUES
Brew Lockout
YES
BREW VOLUMES:
Small Batch
64 oz.
Medium Batch
128 oz.
Large Batch
192 oz.
BYPASS PERCENTAGE:
Small Batch
0%
Medium Batch
20%
Large Batch
20%
PULSE BREW TIMES:
Small Batch
40 (1st on) - 10 (off) - 5 (last on)
Medium Batch
OFF
Large Batch
OFF
PREINFUSION TIMES:
Small Batch
OFF
Medium Batch
OFF
Large Batch
OFF
DRIP OUT TIMES:
Small Batch
1:00
Medium Batch
1:30
Large Batch
2:00
ENABLE ADS
YES
BREW TEMPERATURE
200˚F (93˚C)
READY TEMPERATURE
195˚F (91˚C)
REFILL
155
SPRAY (OZ/MINUTE)
39.2
BYPASS (OZ/MINUTE)
24.1
FUNNEL DETECT
YES
SERVER DETECT
YES