Page 38
PROGRAMMING THE BREWER (cont.)
EXIT TO
NEXT FUNCTION
SCREEN
EXIT TO
NEXT FUNCTION
SCREEN
PRESS AND RELEASE
® SYMBOL
PRESS AND RELEASE
® SYMBOL
NEXT COMPONENT
TO BE TESTED
TEST OUTPUTS?
NO YES
TEST SWITCHES?
NO YES
LEFT BREW VALVE
ON NEXT OFF
125.0 KHZ. 4
4 125.0 KHZ.
NOTHING PRESSED
TEST FREQUENCY?
NO YES
SERVICE TOOLS?
NO YES
P2610
5. When finished, press NEXT to advance counter
screens until the display reads BREW COUN-
TERS. Press and release NO to advance to the
next function screen, or press and release either
ON/OFF switch on the front switch panel to exit
the BREW COUNTERS function and return to the
MAIN SCREEN.
FUNNEL DETECT (optional)
This function allows the operator to prevent the
start of a brew cycle if a Smart Funnel is not positioned
correctly in the funnel rails.
Procedure to set funnel detect:
1. Press and hold the upper right hidden switch until
display reads UNITS. Release the switch. Continue
to press and release switch until display reads
FUNNEL DETECT.
2. NO or YES should be flashing to indicate the cur-
rent setting.
4. Select YES to prevent brewing if a Smart Funnel is
not correctly situated in the rails. If this function
is activated and a brew cycle is attempted with the
funnel not properly situated, the display will read,
FUNNEL NOT IN PLACE, until one is in place.
5. Select NO to allow brewing without a Smart Fun-
nel in place. This is selected when brewing with a
funnel other than a Smart Funnel (a regular brew
funnel).
6. When finished, press and release DONE. This will
retain the changes, exit this function screen and
advance to the next. Another alternative is to press
either ON/OFF switch located on the front switch
panel to exit the FUNNEL DETECT and return to
the MAIN SCREEN.
P2721
FUNNEL DETECT ?
NO
DONE
YES
BREW COUNTERS (cont.)
SERVICE TOOLS
This function allows the testing of individual com-
ponents and the ability to check switches for proper
function. This function also tests the Soft Heat
®
server's
status on the brewer (in place or removed), and the
funnel sensor coil's frequency (diagnostic tool for
troubleshooting purposes only).
Testing individual components (outputs):
This will allow the operator to test the operation
of individual components and outputs of the brewer.
The components that can be individually tested are as
follows:
Left Brew Valve
Left Bypass Valve
Left Funnel Lock
Left Server
Right Brew Valve
Right Bypass Valve
Right Funnel Lock
Right Server
Refill Valve
Tank Heaters
Heater Contactor
35058.1 071205