background image

SHALLOW WELL APPLICATION

SEE DIAGRAM ON PAGE 7

Cut the desired length of poly pipe to run from the top of the well to the pumping level. 

Smooth the pipe cuttings with your round file. (Check that no cut-out parts are left inside 

of the pipe. This may block the pump ejector or impeller). Tape male adaptor threads with 

teflon tape and thread adaptor into the foot valve. Slide 2 stainless steel clamps over one 

end of pipe and use torch to soften pipe. Insert the male adaptor and foot valve into this pipe 

end. Tighten clamps with screwdriver when cool. 

For security against leaks, we suggest 

that you install 2 stainless steel clamps on each adaptor.

Insert the well seal elbow through the opening of the seal.

Slide 2 stainless steel clamps over the free end of the previously cut pipe and soften pipe 

with your torch. Attach pipe to the well seal elbow (end protruding at bottom of well seal). 

Tighten clamps with screwdriver when cool.

Install the well seal and piping assembly into your well casing. Tighten down the well seal 

bolts using your adjustable wrench.

Install your pump in the house, on a sound foundation, as close as possible to the basement 

wall. Locate the suction inlet in the front of the pump body. Thread an adaptor into inlet using 

teflon tape. Do not over tighten.

Cut the desired length of pipe from pump location to the well seal and connect both ends 

using the previous  way, with stainless steel clamps and torch. 

Do not fill in your trench to 

the house until you have checked for any leaks in your connections or trouble in your 

water system.

Sand or well points are limited to areas where water bearing sand or gravel lies below the 

surface, and where there are no boulders or rocks to interfere with the driving into the ground 

of the point.

The amount of water any “one” well point will supply is usually rather limited. Sometimes, it is 

necessary to use more than one point to increase the supply of water, entering to the pump’s 

suction.

IMPORTANT : IF USING WELL POINTS  A CHECK VALVE MUST BE USED IN THE SUCTION 

PIPE LEADING TO THE SUCTION INLET, AS CLOSE TO THE PUMP AS POSSIBLE, TO 

KEEP THE SUCTION LINE AND PUMP WELL PRIMED.

To facilitate servicing at a later date, you may use a pitless adaptor and a sealed well cap 

instead of an elbow and a well seal as described in steps 3 and 4.

CONTINUE ON PAGE 5 & 6 FOR TANKS AND ELECTRICAL INSTALLATION STEPS

STEP 2

STEP 3

STEP 4

STEP 5

STEP 6

STEP 7

for sand

or well

points

4

Summary of Contents for 506121SW

Page 1: ...W 2015 ANDOTHERPRODUCTS 506127S 506128S 506131S etc Please read these instructions carefully Failure to comply to instructions and designed operation of this system may void the warranty 2018 BURCAM...

Page 2: ...750929 6 x 1 1 1 well seal elbow 750860 2 1 male adaptors 750865 or 750871 8 1 stainless steel clamps 750885 Teflon tape Tank installation Desired length of 1 braided hose 750919 to link up from pump...

Page 3: ...tion should be considered as well to provide the pump an environment for long life Locating the pump as close as possible to the water source will reduce friction losses encountered in the suction pip...

Page 4: ...close as possible to the basement wall Locate the suction inlet in the front of the pump body Thread an adaptor into inlet using teflon tape Do not over tighten Cut the desired length of pipe from pum...

Page 5: ...ir at the snifter valve 2 PSI below pressure switch ON setting Turn power back on to pump Your tank is now properly precharged Run the pump through a few cycles to verify that it works properly Other...

Page 6: ...voltage See above drawing on right The pressure switch setting start stop 20 40 or 30 50 has been made at the factory Adjustments may be done to give other operating pressures Adjustment or modificati...

Page 7: ...well seal and piping into well casing STEP 2 Cut poly pipe and install the check valve Check valve close to pump STEP 3 Insert well seal elbow through the seal and attact to pipe STEP 7 You may insta...

Page 8: ...djust air pressure To home s plumbing distribution line Pressure switch 1 4 connection if not included with the pump Pressure gauge 1 4 connection Drain valve 1 2 connection 1 MNPT or 3 4 FNPT connect...

Page 9: ...ump bracket 20 506383 Motor flange cap screw 21 506074GP Fan cover Ref Part Description 22 506073W Motor fan 23 506072GP Motor end bell 24 506385 Wave spring washer 25 350335 Motor bearing fan side 26...

Page 10: ...ir bubbles in water cavitation Airlogged tank galvanized Turn switch to on position Replace Reset Clean Replace Replace Prime with clean water Check pipe and pipe connections Clean Clean Check foot va...

Reviews: