background image

© 2018 BURCAM  Printed in Canada 506516

INSTALLATION

INSTRUCTIONS

Please read these 

instructions carefully.  

Failure

 to comply  

to instructions  

and 

designed

 operation of 

this system,

 may 

void

 the

 warranty.

Your pump has been carefully packaged at  

the factory to prevent damage during shipping.  

However, occasional damage may occur due  

to rough handling. 

Carefully inspect your pump

 

for damages that could cause failures. Report any 

damage to your carrier or your point of 

purchase.

MODEL

506518SS

AND BY-PRODUCTS LIKE

506547SS

506548SS,

ETC.

JET PUMP

506537SS

506538SS

506541SS

Factory set voltage 115 V  

Connecting volatge changing :

Before changing the voltage connection :

A) Ensure the power to the pump is disconnected.

B) Open motor junction box cover.

C) Please select the up knob position for 115 V    

     or down knob position for 230 V.

D) Connect to appropriate power source.

E) Close motor junction box.

2190 Dagenais Blvd. West

Laval (Quebec)

Canada

H7L 5X9

Tel. : 514.337.4415

Fax : 514.337.4029

info@burcam.com

see us at

 

www.burcam.com

Summary of Contents for 506518SS

Page 1: ...ailures Report any damage to your carrier or your point of purchase MODEL 506518SS AND BY PRODUCTS LIKE 506547SS 506548SS ETC JET PUMP 506537SS 506538SS 506541SS Factory set voltage 115 V Connecting volatge changing Before changing the voltage connection A Ensure the power to the pump is disconnected B Open motor junction box cover C Please select the up knob position for 115 V or down knob positi...

Page 2: ...male adaptors 750865 or 750871 8 1 stainless steel clamps 750885 Teflon tape Tools Screwdrivers hacksaw to cut pipe knife to assist in pipe cutting round file to smooth pipe ends pipe wrench adjustable wrench to tighten fittings A B C D NOTICE This unit is not designed for applications involving salt water or brine Use with salt water or brine will void warranty Tank installation Desired length of...

Page 3: ...eratures and good ventilation should be considered as well to provide the pump an environment for long life Locating the pump as close as possible to the water source will reduce friction losses encountered in the suction pipe Friction losses in the suction pipe must be taken into consideration when the horizontal offset is greater than 50 feet The suction pipes should be increased from 1 to 1 1 4...

Page 4: ...ate the suction inlet in the front of the injector Thread an adaptor into inlet using teflon tape Do not over tighten Cut the desired length of pipe from pump location to the well seal and connect both ends using the previous way with stainless steel clamps and torch Do not fill in your trench to the house until you have checked for any leaks in your connections or trouble in your water system San...

Page 5: ...ter valve 2 PSI below pressure switch ON setting Turn power back on to pump Your tank is now well precharged Run the pump through a few cycles to verify that it works properly Other types of tanks may be used as galvanized standard tanks epoxy or glass lined tanks These products do not achieve the benefits of the captive air tanks Epoxy or glass lined tanks with float have to be precharged by the ...

Page 6: ...er operating pressures Adjustment or modification of start stop setting of pressure switch have to be done carefully Turn adjustment nut half turn at a time Turn nut 1 clockwise to raise start and stop pressure setting Never turn nut 2 This will change the 20 PSI range between start and stop pressure and may damage your tank s bladder or modify the efficiency of your water system Check system oper...

Page 7: ...and piping into well casing STEP 5 Install your pump and thread an adaptor into inlet STEP 6 Cut poly pipe and connect both ends STEP 7 You may install one or more sand points to increase the supply of water Check valve close to pump SHALLOW WELL APPLICATION STEP 2 Cut poly pipe and install the foot valve 7 ...

Page 8: ...ection Pressure gauge 1 4 connection 1 MNPT or 3 4 FNPT connection Relief valve for pumps with more than 75 PSI of capacity 1 2 connection To home s plumbing distribution line From well Snifer valve to adjust air pressure STEP 9 Connect the pump discharge to the tank T 8 ...

Page 9: ...uge 4 510003 Pump boby screw 6 5 510004 Venturi O Ring 6 510005 Venturi Diffuser 7 510006 Impeller 8 510007 Washer 9 510008 Mechanical seal 10 510009 Seal plate O Ring REF ITEM DESCRIPTION 11 510010 Seal plate 12 510011 Water slinger 13 510012 Motor 14 510013 Capacitor 15 510014 Jonction box cover 16 510015 Motor foot 31 510016 Tube fitting 32 510017 Tube 33 510018 Pressure switch 1 2 4 6 9 5 7 10...

Page 10: ...ion line Gaz in water Airlogged tank galvanized Turn switch to on position Replace Reset Clean Replace Replace Prime with clean water Check pipe and pipe connections Clean Clean Check foot valve level Water level lower than lift capacity Check voltage Check foot valve level Clean Too small or dirty pipe Check voltage Check all pipes for leak Check power cable and voltage Reset or replace Clean Dra...

Reviews: