ProfiScale MULTI PS 7455
Englisch
23
1. During usage of this meter, the user needs to consider these safety rules:
· Protection against hazards of electrical current.
· Protection against a misuse of the device.
2. Please check the meter for damages before commissioning and only
use the device if no damages are recorded.
3. The measurement lines need to be in an immaculate condition.
Make sure that the insulation of the lines are not damaged and / or the
conductors of the meter are not exposed.
4. Compliance with safety standards can be guaranteed only when using the
included measurement lines.
5. Before using, select the appropriate input jack, function and the measuring
range.
6. Always attach the black measurement line first, afterwards the red one.
For removing, do so conversely.
7. Only use the device with the backside casing and only if the casing
is properly secured.
8. Before you turn the selector switch to choose another measuring range,
remove the measurement lines from the about to be tested circuit.
9. Never exceed the prescribed limits of the respective ranges.
Be especially careful when measuring near the limit range.
10. If the meter is connected with another circuit, do not touch any free
connectors.
11. Do not measure electric voltage if the voltage of the connections exceeds
600 V.
12. Always be careful with measurements with a voltage of over 60 V DC or 30 V
AC rms. During the measuring, hold your fingers behind the boundaries of
the measurement lines.
13. Never connect the measuring lines to a circuit if the selector switch is
positioned on one of the following measuring ranges: Current measurement,
electrical resistance measurement, temperature measurement and diode test
or continuity check mode.
14. Never conduct resistance measurements, temperature measurements, diode
tests and continuity checks on energised circuits.
15. Make sure that before measuring of diodes, electrical resistances or before
continuity checks the about to be measured object is volt-free and all
capacitors are fully discharged.
16. Check the function of the meter with measuring a known circuit first. If you
detect a deviation, do not use the meter any longer.
17. If you detect any errors or anomalies, the device cannot be used anymore
and needs to be professionally checked.
18. Never try to fix the meter yourself.
19. Do not dismount the device in order to avoid functional errors.
20. Only let the meter be repaired by qualified professionals and only with
genuine parts to obtain the device’s safety and warranty.
21. Before you open the battery case cover or the casing of the meter, always
remove all measurement lines from all tested circuits.
22. If you see the battery symbol
on the display, immediately change the
battery to avoid flawed measuring results. An accuracy of the meter is not
reliable in this state which could lead to an electric shock.
23. Always turn OFF the meter when not in use.
24. If the meter is not used for a longer period of time, the battery should
be removed to prevent damages of the device.
25. To prevent fire, only use fuses with respective voltage and loading capacity:
FF 400 mA H 600 V or FF 10 A H 600 V.
26. Keep the device away from children and unauthorised persons.
27. Do not use any abrasive cleaners or solvents for cleaning your device.
Use a wet cloth and only mild cleaners.
28. Do not use the device in approximate range of flammable or explosive gases.
29. Handle the device carefully and do not drop it.
30. Do not store the device in direct sunlight, at high temperatures,
high humidity or precipitation.
31. Store the device dry and safe.
32. Avoid contact with water and dust.
Structure