The illustration below describes the error messages 

on the display when a fingerprint is created is or 

when the safe is opened.

Error message

Solution

Too fast! 

Please repeat

Move your finger slowly 

across the sensor.

Too tilted! 

Please repeat

Move your finger flat across 

the sensor.

Too short! 

Please repeat

Move your finger across the 

sensor so that more area of 

your fingerprint can be read.

Position in the 

middle and repeat!

Position your finger in the 

middle of the sensor.

Wrong code!

Enter a valid code.

No admittance!

An unsaved fingerprint has 

been used. Repeat with a 

fingerprint that has already 

been created.

Error messages

Technical details

Number of administrator 

codes:

1

Number of user codes:

9 (max.)

Number of 

fingerprint codes:

20 (max.)

Blocking times:

After an incorrect code is entered 3x, 5 minutes, 

thereafter always 10 minutes

Power supply:

4x AA MIGNON LR6 ALKALINE

Date/time:

Updatable (firmware):

History number:

2,000

Battery replacement

Remove the two screws on the underside of the  

lock electronics. This will require a Torx T 8 screw-

driver.

Let the cover slide out together with the batteries. 

Remove the old batteries and dispose of them 

according to the disposal instructions on page 

15. Replace the batteries with four new 1.5 V AA 

Mignon batteries and according to the correct 

polarity. For this purpose, illustrations are shown on 

the battery holder. Please use branded batteries and 

no rechargeable batteries. 

Push the cover and batteries back into the locking 

electronics and screw them tight.

You can see the battery status at any time using  

the battery level indicator at the top right of the 

display. If the battery capacity is running low,  

a corresponding message appears on the display: 

When this notice appears, change the batteries  

as soon as possible.

Warranty

Disposal of the device

BURG-WÄCHTER products comply with the technical standards at the time of 

production and adhere to our own quality standards. The guarantee only covers 

defects which can be proved to have resulted from production or material defects 

at the time of purchase. The warranty ends after two years, further claims are 

excluded. Defects and damage caused by e.g. transport, incorrect operation, 

improper use, wear etc. are excluded from the warranty. The batteries are not 

included in the guarantee. A short description of any defects identified must be 

made in writing and the device returned to the place it was purchased, together 

with the original packaging. After the device has been tested, and within a 

appropriate period of time, the guarantor will decide whether or not to repair or 

exchange the item.

Attention:

In order to deliver a flawless and high quality product to you and to better assist 

you in case of service or repair, it is necessary that faulty or defective devices 

along with the valid administrator code be presented to your dealer together 

with the original documentation.

For returns, all undamaged device parts must furthermore be in the factory 

setting due to your right of revocation. Failure to comply with this will invalidate 

the warranty.

Dear customer,

please help us avoid unnecessary waste. Should you intend to dispose of this 

device at any time, please remember that many components of this device 

contain valuable materials that can be recycled.

Printing and typesetting errors as well as technical changes reserved.

Please be aware that electrical and electronic equipment and 

batteries marked in this way must not be disposed of with house-

hold waste but collected separately. Please obtain information 

on the collecting points for electrical waste from the responsible 

authority of your city/municipality.

BURG-WÄCHTER KG hereby declares that this device complies 

with the Directives 2014/30/EU, (EMC) and 2011/65/EU (RoHS). 

The complete text of the EU Declaration of Conformity is availa-

ble at the following Internet address: www.burg.biz

Safety recommendation

Please clean the keyboard operating surface periodically with a microfibre cloth 

(e.g. glasses cleaning cloth for spectacles) to remove any fingerprints on the 

keyboard surface.

Too fast!

Please repeat

FUNC:

Wrong code!

FUNC:

EŽĂĚŵŝƩĂŶĐĞ͊

FUNC:

Please change

ďĂƩĞƌŝĞƐ͊

FUNC:

7

Summary of Contents for SECUTRONIC

Page 1: ...yar 51 Românesc 58 Português 65 Dansk 72 Suomalainen 79 Norsk 86 Svenska 93 Polski 100 Slovensko 107 Espanol 114 български 121 Hrvatski 128 русский 135 ελληνικά 142 Eestlane 149 Latvietis 156 Türk 163 Lietuvis 170 Language SecuTronic TRSE 12H BURG WÄCHTER KG Altenhofer Weg 15 58300 Wetter Germany ...

Page 2: ...lay runs countsdown It is not possible to open the safe during this period even with a valid user or administrator code Please take care to ensure codes do not fall into the wrong hands Therefore store the codes in a safe location so that they can only be accessed by author ised persons In the event you lose a code the lock must be set to a new code The factory code must be changed as soon as the ...

Page 3: ...sign code Assign fingerprint Delete Time functions Set time Set date Automatic ST WT Delay time Programming Database update Firmware update Reorganise Processes Display Save Setup Register FP reset Generate AES key Info System info System check Description of the menu functions Code Change menu Change the administrator code and the user codes We would like to point out that for security reasons th...

Page 4: ...s Confirm with Mainmenu Administrator User Createfinger appears Scroll with the 1 or 2 key until the Create fingerprint menu item is highlighted Confirm with Enter the administrator code to acquire the authorisation for programming Programmfinger appears Move the finger from the top to bottom centrally and a number of times over the sensor The display will either prompt you to repeat the process f...

Page 5: ...ator User appears Confirm with Mainmenu Administrator User Delete appears Scroll with the 1 or 2 key until the menu item Delete is highlighted Confirm with Enter the administrator code to acquire the authorisation for programming You can use the keys 1 or 2 to scroll until the user is marked whose code is supposed to be deleted Confirm with Datahasbeendeleted appears Press any key Menu Administrat...

Page 6: ...ey Menu Administrator Programming Menu Administrator Programming Firmware update Menu Administrator Programming Reorganise Menu Administrator Programming Databaseupdate A firmware update installs the latest software version Reorganise sorts the database This function is not enabled at present Please ensure that the batteries are full before updating the firmware Please copy the new firmware versio...

Page 7: ...king mechanism Switch on the lock using the key The press The Mainmenu appears Scroll with the 1 or 2 key until the menu item Administrator is highlighted Confirm with Administrator appears Scroll with the 1 or 2 key until the menu item Setup is highlighted Confirm with Scroll with the 1 or 2 key until the menu item FP Reset is highlighted Confirm with Enter the administrator code to acquire the a...

Page 8: ... which can be proved to have resulted from production or material defects at the time of purchase The warranty ends after two years further claims are excluded Defects and damage caused by e g transport incorrect operation improper use wear etc are excluded from the warranty The batteries are not included in the guarantee A short description of any defects identified must be made in writing and th...

Page 9: ...SecuTronic 178 Notes 8 ...

Page 10: ...SecuTronic 179 Notes 9 ...

Page 11: ...www burg biz BURG WÄCHTER KG Altenhofer Weg 15 58300 Wetter Germany www burg biz SecuTronic SWI HBG SECUTRONIC TRSE 12H FP 15052020 ...

Reviews: