2.1 Description of basic functions

You can program your lock based on the following description.  
You can see the programming instructions on the display. To program the 
lock (enter into the menu), please press the “Function” key, when the 
symbol “M” is displayed. You can move within the menu using the keys “1” 
scroll up (symbol on display) and “2” scroll down (symbol on display). When 
the symbol “<” is displayed, you can use the “Function” key to skip to the 
next higher menu level, and choose a particular menu item using the “Enter /
On” key. The battery symbol indicates the current battery status:

 

Battery full

 [ ] [ ] [ ]  

Battery empty (please replace the batteries) 

The batteries are replaced in a way depending on the safe fittings. 
Battery replacement page 22

2.2 Description of programming and user mode

Please find the menu structure shown on the following pages. Also the 
navigation is indicated. Additionally, each of the menu items is clarified:

Code change menu

Change of the administrator and user codes

Language / Sprache menu

Language setup

E-Key synchronization menu

In this program, the channel of the E-Key is adapted to the channel of the 
input unit.
This function is necessary when the radio channel of an input unit is 
modified, although other radio keys (with the old channel setup) are still 
logged.

Info menu

–  Indication of version and serial number
–  SNA: Lock serial number (via type in the Administration code)

Administrator menu

This includes all the menus that can be used only with the administrator 
authorizations. They include:

–   

Create User:

 

Users can be created here. A user has either a code, or an E-Key, or both. 
A separate user is always created for a fingerscan. 
Anatomically, there are people, the fingerprints of whom are not 
sufficiently articulated for the system.

–   

Assign E-Key:

 

An E-Key can be additionally assigned to a selected user here.

–   

Delete:

 

Users and E-Keys can be deleted here. When a user is deleted, also the 
code and the E-Key belonging to the user are deleted. When an E-Key  
is deleted, the user is retained. To delete a fingerscan, the corresponding 
user has to be deleted. To delete all the fingerscans, please use the  
“FS-Reset” function (see below).*

–   

Time:

 

Entry of the time and calibration of the clock. The clock is automatically 
calibrated between two specific times. Exceptions are a replacement of 
batteries and the switchover from summer to winter time.

–   

Date:

 

Entry of date

–   

Radio Channel:

 

The radio channel can be set up here (12 channels to select from). This 
can be required when the radio channel is already used by another 
application, e. g. WLAN. In case of collision with WLAN systems, a space 
of three channels is recommended.

–   

Priority:

 

In case the door cannot be opened after several attempts with the E-Key, 
the priority of the door can be increased by this function. Inversely, also 
the priority of other door within the direct environment can be reduced.

–   

Restructure:

 

The use of this function is recommended when several users have been 
deleted.

–   

Register:

 

When either the lock unit or the keyboard is replaced, the two units are 
newly tuned to each other.

–   

FS-Reset*:

 

All the stored fingerprints are deleted, however, the corresponding users 
are retained. Please select this menu and follow the instructions on the 
display also in case of repeated error functions related to the use of 
fingerscans. These fingers could not be stored because of security reasons. 

Summary of Contents for Tresor TRSE 6000

Page 1: ...ER KG Altenhofer Weg 15 58300 Wetter Germany TRSE 6000 TRSE 6000 TRSE 6000 FS TRSE 6000 FS BA MA TESE 6000 dp fsc 02 2012 Bedienungsanleitung User Manual Manuel d utilisation Gebruiksaanwijzing Tresor Nutzen Sie drei Arten zum Öffnen ...

Page 2: ...s are stored in the system with a value of In order to acquire the authorization to open a value of at least 1 must be achieved A pin code with a value of at least must be therefore entered for the opening a value of 1 can be also achieved with an additional fingerscan Attention The values can only be adjusted using TSE Light TSE System and System software When a PIN code user or an E Key user is ...

Page 3: ...as either a code or an E Key or both A separate user is always created for a fingerscan Anatomically there are people the fingerprints of whom are not sufficiently articulated for the system Assign E Key An E Key can be additionally assigned to a selected user here Delete Users and E Keys can be deleted here When a user is deleted also the code and the E Key belonging to the user are deleted When ...

Page 4: ... Channel Admin Setup Priority Delete User Delete E Key Connection Channel Restructuring in progress Free space not available Data are stored Data are stored Data are stored Data are stored Data are stored Data are stored Wrong Code Please repeat Delete Data by pressing ON Taste Priority Admin Setup Restructure Admin Setup Install Keyboard Admin Setup FS Reset E Key in prog Mode cont with ENTER Adm...

Page 5: ...up Create user is displayed Press the On Enter key Create code is displayed Press the On Enter key At this point you are asked to enter the Admin Code factory setting 123456 The indication of User 00x is displayed Please enter the user code and confirm it with ENTER Press the On Enter key FS combination to be confirmed with ENTER is displayed1 Press the On Enter key and accordingly the Function ke...

Page 6: ...ication is displayed At this point enter an additional opening code The instruction Please turn knob is displayed 7 Deleting a finger Press the On Enter key The indication of Code Fingerp is displayed Press the Function key The Change code menu is displayed By pressing the key 2 reach the Administrator menu Press the On Enter key Admin setup Create user is displayed By pressing the key 2 reach the...

Page 7: ...TSE BUSINESS 5000 22 Batterien Batteries Batterijen 2x 1 5V Mignon LR6 Codeeingabe Code entry Entrée code Code invoer 5 Batteriewechsel Replacement of batteries Changer la batterie Batterijwissel ...

Reviews: