background image

PlusConnect™ for 

GatesAir

 3DX Transmitters 

Installation and Operation Manual 

Introduction 

The PlusConnect™ for 

GatesAir

 3DX provides a connection between the 

GatesAir

 3DX 

transmitters and the ARC Plus transmitter remote control system. Transmitter parameters 
are read by the PlusConnect using a serial connection to the transmitter. They are then 
forwarded to a receiving ARC Plus unit via Ethernet. PlusConnect channels can then be 
monitored and controlled via: 

Front panel of the ARC Plus

Web browser, with the web server built into the ARC Plus

PC via optional AutoPilot® Plus software

Optional telephone connection to the ARC Plus.

The PlusConnect is part of the Plus-X™ family of expansion products designed for the 
ARC Plus.  

Important!

 The PlusConnect operates in conjunction with an ARC Plus system. Be sure 

to complete configuration of the ARC Plus before adding the PlusConnect to the system. 

Installation Tip

 

Even though the ARC Plus and the PlusConnect may be operated on different subnets, it 
is strongly recommended that the PlusConnect be installed on the same LAN as the ARC 
Plus. In a network failure, a PlusConnect on the same LAN as the ARC Plus benefits 
from the macros, event logging and alarm reporting handled onboard the ARC Plus.  

Unpacking 

The PlusConnect for 

GatesAir

 3DX ships with the following: 

Manual

PlusConnect unit

Power cord

Null modem cable

DB-9M to DB-9F straight-through serial cable

10’ Shielded CAT5 cable

Summary of Contents for PlusConnect

Page 1: ... to the ARC Plus The PlusConnect is part of the Plus X family of expansion products designed for the ARC Plus Important The PlusConnect operates in conjunction with an ARC Plus system Be sure to complete configuration of the ARC Plus before adding the PlusConnect to the system Installation Tip Even though the ARC Plus and the PlusConnect may be operated on different subnets it is strongly recommen...

Page 2: ...nfig mode 4 HyperTerminal will display the current configuration settings for the PlusConnect If this is the first time you are setting up the PlusConnect default values will be returned 5 Enter new configuration settings for the PlusConnect where prompted You will be asked to configure IP address The network address of the PlusConnect unit Subnet mask The subnet mask for the PlusConnect Port numb...

Page 3: ...shielded Ethernet cable or equivalent 3 Apply power to the PlusConnect Software Configuration Now that the PlusConnect is installed on the network and connected to the transmitter you are ready to add the PlusConnect to the ARC Plus configuration using AutoLoad Plus software AutoLoad Plus is included with the ARC Plus and may also be downloaded from the support section of www burk com Configuratio...

Page 4: ...ogram Files Burk Technology AutoLoad Plus Plus X 5 Enter the IP address and port number of the PlusConnect These should be the same settings you used when you configured the PlusConnect with HyperTerminal 6 Check the Map default set of channels box if you wish to automatically add the most commonly used PlusConnect parameters to the ARC Plus recommended In the case of the 3DX the default set of ch...

Page 5: ...ls Status Channels or Commands tabs as appropriate 1 Within any of these tabs click the Override button to change a channel s assignment from a traditional I O channel to a Plus X channel 2 When the Override Channel dialog appears select Plus X channel and choose the Plus X device from the list Then select the PlusConnect channel you wish to use instead of the I O channel 3 Press OK Once mapped th...

Page 6: ...a custom view in AutoPilot plus using a pre built template specific to your transmitter model In order to use templates you must map the default set of channels to the ARC Plus during setup If you have mapped a custom set of channels you can still use custom views to display them but the templates will not function as intended To create a custom view with a PlusConnect template 1 Open the custom v...

Page 7: ...tion on using the ARC Plus to monitor and control the remote site please see the ARC Plus installation and operation manual Note that the PlusConnect channels are routed only through the ARC Plus unit specified during PlusConnect configuration In order to access the transmitter parameters by any means the ARC Plus unit must be powered and connected to the network Troubleshooting Connection Errors ...

Page 8: ... Burk Technology A return authorization must be obtained before returning any equipment Materials returned under this warranty must be shipped freight prepaid and insured in the original shipping carton or suitable substitute to Burk Technology Inc 7 Beaver Brook Road Littleton MA 01460 Repairs not covered under this warranty will be made at prevailing shop rates established by Burk Technology THE...