Troubleshooting
9.2.
Malfunction
possible cause
remedial action
Valves do not switch
No or inadequate operating voltage
Check the electrical connection
→
Ensure the operating voltage according to
→
type plate.
Manual actuation not in neutral
position
Move manual actuation to zero position
→
Inadequate or no pressure supply
Design the pressure supply with the largest
→
possible volume (even for upstream devices
such as pressure controllers, maintenance
units, shut-off valves, etc.)
Minimum operating pressure
≥
2.5 bar