background image

3.6

 

Open Control Panel to verify the presence of your audio 

device and channels

3.7  Set BMB5 front panel to INT or EXT 

•  The BMB5 Motherboard supports 44.1kHz, 48kHz, 88.2kHz and 96kHz sample 

rates. 

•  When using the B16 on internal clock, set to INT, and use Sample Rate button to 

set desired sample rate. 

•  If using external word clock, set to EXT. B16 Sample rate should follow external 

clock.

3.8  Open ArchWave USB Driver Control Panel 

“Synchronisation” settings

3.9

3.10

Image 17: BMB5 front panel. Set Clock Control to INT or EXT.

SECTION 

3

7

Image 18: BMB5 front panel. Set Clock Control to INT or EXT.

Image 19: ArchWave USB Driver Control Panel. Select “Synchronisation” 

(3.8), Set Sample Rate (3.9) and Clock Source to Word Clock (3.10)

3.8

Summary of Contents for B16-BMB5 MOTHERSHIP

Page 1: ...B16 BMB5 MOTHERSHIP BMB5 Rev A Rom A1 USB 2 0 Quick Start Guide Section 1 Getting Started Section 2 BMB5 Quick Start for Mac OSX Section 3 BMB5 Quick Start for Windows Revision 1 August 28 2018...

Page 2: ...been pre installed skip to page 2 step 1 7 1 3 Remove lid 1 Remove 9 screws on top and 2 on each side Image 1 2 Push lid up from card slot Image 2 1 4 Daughter Card Installation 1 Make sure each card...

Page 3: ...n connector is attached properly See Image 6 be low 1 6 Attach lid with all screws 1 7 Install vent above B16 Mothership Image 6 Attach the ribbon cable and 2 pin connector for BAD4 and BDA8 to the fr...

Page 4: ...ed Computer running Mac OS X and a USB port B16 Mothership with BMB5 Motherboard USB 2 0 Cable 2 1 Connect USB cable to BMB5 Motherboard and to USB port on host DAW computer power on 2 2 Set BMB5 fron...

Page 5: ...t desired sample rate in Audio MIDI Setup See image 11 above 2 7 Open your DAW application and select uNet 2500 as your audio device The following examples are using Cubase For Logic see page 10 Go to...

Page 6: ...ry time you change Sample Rate Buffer Size or Clock Source 1 Save and Quit your DAW application 2 Unplug the USB cable from the computer 3 Plug USB cable back in to computer 4 Restart your DAW applica...

Page 7: ...3 2 Start driver setup 3 3 Only when prompted Power on B16 connect BMB5 Mother board to computer with USB cable 3 4 Continue through setup and restart computer once completed 3 5 After restart find US...

Page 8: ...ate button to set desired sample rate If using external word clock set to EXT B16 Sample rate should follow external clock 3 8 Open ArchWave USB Driver Control Panel Synchronisation settings 3 9 3 10...

Page 9: ...rate in ArchWave USB Driver Control Panel See Image 19 page 7 3 11 In your DAW application select uNet 2500 as your audio device The following examples are using Cubase Go to your DAW application sett...

Page 10: ...g B16 BMB5 With Logic Pro 4 1 Select uNet_2500 as your device 1 Open Audio Preferences Logic Pro X Preferences Audio 2 Select uNet_2500 for both Output Device and Input Device Image 22 Select uNet_250...

Page 11: ...10...