Page 13
4. I
NSTALLATION
I
NSTRUCTIONS
Before installation, ensure that the local distribution conditions (identification of the
type of gas and pressure and the adjustment of the appliance are compatible)
4.1.
General Safety Requirements
The installation of the fire should also follow the recommendations of the following current
British Standards (or equivalent):
BS 6891
Pipe work Installation
BS 5440: Pts 1 & 2
Flues and Ventilation
IGE/UP/7 IGE
Document for gas installations
in Timber Frame Buildings
(Available from Institute of Gas Engineers & managers)
BS5871-2 – 2005 Part 2:
Inset live fuel effect gas fires of heat input not
exceeding 15kW.
BS EN 1856
Chimneys - Requirements for metal chimneys - System
chimney products
BS EN 1858
Chimney – Components – Concrete flue blocks
BS 715
Metal flue boxes
It is important for correct combustion of this fire that the imitation fuel is placed in accordance
with the instructions given in this and associated booklets. Only approved imitation fuel,
available from Burley Magiglo, should be used with this appliance.
Combustible shelves or materials must only be fitted above the fire in accordance with the
instructions given in this and associated booklets.