Installation / Service / User Manual

                                                                          BURNERTECH 

 
 

 

3  Technical Information 

 

3.1

 

Technical Data 

 

MODEL                                                    INVERTERJET  50/M              INVERTERJET 90/M       

Type                                                               Pre-Mix Burner                         Pre-Mix Burner 

Fuel                                                              Natural Gas/LPG                       Natural Gas/LPG 

Power Min-Max [kW]                                            10-50                                        18-90                                                                  

Modulation Range                                                  1:5                                            1:5 

Nominal Voltage Range [VAC]                           120/230                                    120/230 

Frequency [Hz]                                                      50/60                                       50/60 

Phase                                                                       1 ~                                          1 ~ 

Fan Current Draw Max [A]                                      1.9                                          1.9 

Gas Connection                                                  

1/2 “BSP                                 1/2 “BSP 

Gas Pressure Min - Max [mbar]                           10 

– 60                                    10 – 60     

 

 

                                 

3.2

 

Technical Description of the Burner Parts 

 
The Inverterjet 50M and 90M have the following technical description of the parts. 

 

 

              
 
 
 
 
 
 

1   Controller 
2   Gas Connection Flange 
3   Fan Housing 

4   Inverterjet Burner Head 
 

5   

Ignition Electrode

 

6   

Venturi

  

7   Gas Valve 
8   Ionisation Probe (Not shown) 
 

 

Summary of Contents for Inverterjet 50M

Page 1: ...rs Ltd INSTALLATION SERVICE USER MANUAL Inverterjet Burner Series Ultra Low NOx Burners MODEL PRODUCT CODE CLASS Inverterjet 50M 91320 Modulating Pre mix Burner Inverterjet 90M 91323 Modulating Pre mi...

Page 2: ...l Installation 12 4 5 Basic Electrical Safety 12 4 5 1 Burner Wiring Diagrams Inverterjet 50 M 90 M 13 5 Commissioning 14 5 1 Commissioning procedure 14 5 1 1 Turning on the Burner 15 5 1 2 Commission...

Page 3: ...cal Wiring Diagram in this burner manual For Burner Installation Operation advice please call Burnertech Technical on 0044 0 1204 393222 To ensure maximum product reliability we advise and request tha...

Page 4: ...Installation Service User Manual BURNERTECH 3...

Page 5: ...3 Installation Before connecting the burner make sure that the burner rating matches the appliance requirements and that both gas and electrical services are adequately rated The burners are designed...

Page 6: ...manufacturer s instructions as detailed in this manual Always ensure that inlet or exhaust grilles are unobstructed and filters cleaned regularly The Maximum operating conditions for the Gas Valve an...

Page 7: ...Nominal Voltage Range VAC 120 230 120 230 Frequency Hz 50 60 50 60 Phase 1 1 Fan Current Draw Max A 1 9 1 9 Gas Connection 1 2 BSP 1 2 BSP Gas Pressure Min Max mbar 10 60 10 60 3 2 Technical Descript...

Page 8: ...dimensions and weight The diagrams below show the major dimensions and weight of the burner MODEL A B C D1 D2 H L W Weight mm mm mm mm mm mm mm mm kg Inverterjet 50 M 92 71 91 101 6 170 244 365 238 5...

Page 9: ...pending on parameter setting 0 10 V control a DC voltage between zero and ten volts can be applied to connector X3 Pins 8 16 At zero volt the fan will run on Minimum Fan speed At ten volt the fan will...

Page 10: ...Installation Service User Manual BURNERTECH 9 3 4 2 2 Lock out reset The Control can be reset by depressing the internal external reset button 4 Installation 4 1 General Installation Information...

Page 11: ...r the burner Mounting Plate Appropriate dimensions are shown below When installing the burner please be sure to use the gasket provided for sealing and insulating between the Mounting Plate and the be...

Page 12: ...front of the Gas connection flange at the rear of the burner 2 Check the thread on the flange and ensure that there is no debris in the threads 3 Connect the corresponding gas pipe fittings to the Ga...

Page 13: ...Installation Service User Manual BURNERTECH 12 4 4 Electrical Installation The electrical wiring diagram for the Burners are shown in the following page 4 5 Basic Electrical Safety...

Page 14: ...Installation Service User Manual BURNERTECH 13 4 5 1 Burner Wiring Diagrams Inverterjet 50 M 90 M X3 Microfit X2 Communication see note X1 Minifit...

Page 15: ...e ventilation is available for the safe operation of the burners 4 Establish that the system pipe work is complete full purged and adequate system load and circulation exists to facilitate firing of t...

Page 16: ...adings are within the required tolerance and if an appropriate gas meter is available to conduct a heat input measurement whilst operating at maximum rate to ensure the rate is within 5 of that requir...

Page 17: ...1500 rpm Ignition 30 5 1 3 1 Fan speed adjustment The following flowchart Fan speed control flowchart shows how the fan speed is controlled during a complete burner sequence The basic states are Stan...

Page 18: ...Installation Service User Manual BURNERTECH 17 Flow chart fan speed...

Page 19: ...Installation Service User Manual BURNERTECH 18 6 User Instructions 6 1 Limitations on use of Burner...

Page 20: ...fan to a pre set ignition speed The ignition spark is generated at this point and the Burner will ignite If satisfactory ignition takes place the burner will remain alight and the fan speed will modu...

Page 21: ...m the chamber 7 1 1 The condition of the burner head some discolouration of the burner material is normal but the material should not be cracked or open Under no circumstances should any of the perfor...

Page 22: ...Electrodes Inspect the ignition and flame electrodes if extensive signs of damage are detected they must then be removed and replaced Fan The fan is not a serviceable component Simply ensure it is pos...

Page 23: ...ty times are constantly compared etc Any violation of programmable limits and or internal thermostat functions will lead to an error fault or warning condition Severe error will cause a lockout condit...

Page 24: ...d fan speed is not within 900 RPM of the requested fan speed in 20 seconds error will be generated FAULT 8 Flame circuit error during normal operation of the ignition controller flame circuit is regul...

Page 25: ...red a Windows based software along with a dedicated USB cable and driver is available to enable programming of certain parameters in the control and also to read fault codes etc An example screenshot...

Page 26: ...Installation Service User Manual BURNERTECH 25 7 3 4 Maintenance Notes...

Page 27: ...Installation Service User Manual BURNERTECH 26...

Page 28: ......