background image

16 

 

16.

 

Warranty is Based on the Confirmed Warranty Card 

 

WARRANTY CARD 

 

 

Product type:……………………………………………… 

 

 

Serial number:…………………………………………….. 
 

Year of manufacture:…………………………………… 

 

 

Date of sale:………………………………………….……… 

 
 

 

 

 

 

 

 

 

…………………………………………………………..……. 

 

 

Signature and stamp of the seller 

 

 

WARRANTY TERMS AND CONDITIONS APPLICABLE TO THE BUYER (CONSUMER)  

 

1. These Warranty Terms and Conditions are prepared in accordance with the relevant legal regulations of the Czech Republic, in particular 

Act No. 89/2012 Coll., the Civil Code and Act No. 634/1992 Coll., Consumer Protection Act.  
2. The product is warranted by the seller for a duration of 24 months. The warranty period begins from the takeover of the product by the 

consumer.  In  case  of  necessity  of  commissioning  by  an  authorized  or  professional  company,  the  warranty  period  begins  on  the  date  of 

commissioning of the product if the buyer ordered the commissioning within three weeks of the takeover of the product and provided the 
necessary  co-operation  in  due and  proper  time.  In  the  event  of  failure to  comply  with  this condition,  the  warranty  period  begins at  the 

takeover of the product.  
A longer warranty period is provided for the weldment of the fireplace against burn through with a duration of 84 months. 

3. At the request of the consumer, the seller is required to issue a proof of purchase or service provision with indication of the date of sale of 

the product or the provision of the service, what kind of product or service it is and the price for which the product or service was provided, 
together with the seller’s identification, unless stipulated otherwise by a special regulation.  

4. The warranty covers all manufacturing defects and material defects that have provably occurred during the warranty period.  
5. The warranty does not cover:  

– wear of parts caused by their usual use in normal operation, parts requiring regular replacement and resulting from the life of the part 

itself (especially parts in direct contact with fire such as all seals, glass, glass decorative printing, stops, mechanically stressed springs, etc…) 
according to the provisions of Section 2167 of the Civil Code and:  

– defects caused by mechanical damage, 

– defects caused by poor and improper manipulation (see Instructions for Use),  
– defects caused by connection to an insufficiently dimensioned chimney or low draught chimney, inappropriate handling or use and failure 

to observe the conditions of use and maintenance (see Instructions for Use);  
– if the product is stored and used in a damp and open space or if it is used in such space that does not match the residential environment,  

– in the event of damage to warranty labels and plates with serial numbers,  

–  damage  to  goods  during  transport  (in  the case  of  own  transport).  In  the  case  of  transport  by  an  external transport  service,  the  seller 
reserves the right to inspection at the place where the product was transported. 

– damages resulting from natural disasters, weathering, damage by brute force,  

– if the data in the warranty card or the proof of purchase differ from the data in the data plate. 
6. The warranty extension does not apply to consumables used to repair or replace parts of the product.  

7. Complaints should be registered at the seller from whom the product was purchased. However, if another person appointed for repairs is 
stated in the warranty card, who is close the seller’s place or to the place nearer for the buyer, the buyer shall apply the right of repair at the 

person appointed for warranty repairs. The person appointed for repairs is obliged to make the repair within the time agreed upon the sale 

of the product between the seller and the buyer. 
8. Complaints are only accepted from and handled with the buyer or with a person authorized by the buyer in writing.  

9. The seller is required to provide the consumer with a written confirmation of when the consumer has exercised the right, what is the 

content  of the complaint  and  what form of claim the consumer demands. The seller is also obliged  to notify the buyer in writing of  the 
manner  and  date  of  the  settlement of  the  complaint  within  30  days  or  send  a  written  justification  of  the  refusal  of  the  complaint.  This 

obligation also applies to other persons appointed to perform repairs. 
10. When making a complaint, the buyer is obliged to communicate or supply product data identification (see the serial number on the data 

plate) in addition toa detailed description of the claimed defect (e.g. in what mode and how the defect is manifested, how long after the 

lighting, description of handling of the item before the defect, etc.).  
11. In the first 6 months after the purchase of  the product, the  complaint will be settled as a conflict  with the Purchase Contract  under 

Section 2161 of the Civil Code. In the following months of the warranty period, the complaint settling will be based on whether the defect is 
removable or irreparable. 

12. When making a complaint, the buyer is obliged to prove that the product is being complained about at the seller who sold the product 

and that it is covered by the warranty period. It is best to prove these facts by submitting:  
– the proof of purchase 

– the confirmed warranty card including the handover certificate, if it is part of it. 

13. Other rights and obligations not governed by these terms and conditions are governed by the relevant laws of the Czech Republic. 

Summary of Contents for CARINA S

Page 1: ...Instructions pour l installation service et maintenance des po les chemin e CARINA S 09 2018...

Page 2: ...ire Les po les sont certifi s selon les normes EN13240 Principaux param tres thermo techniques Plan et parametres de base Le contr le de l entr e d air primaire et secondaire est un levier sous la por...

Page 3: ...li rement attention et respectez les consignes de s curit Gr ce la combustion une nergie thermique se lib re ce qui chauffe la surface de la po le la porte de la chambre de combustion les poign es de...

Page 4: ...tion 1 4 h 7 L air de combustion Les po les d pendent de l air ambiant et la diminution de l air de combustion de la pi ce il est n cessaire de veiller la circulation de l air de combustion Durant la...

Page 5: ...de combustion Ne jamais teindre le feu dans les po les foyer Si le po le est en marche le foyer doit tre ferm avec la porte pour viter l chappement du gaz Si le po le est en marche le foyer doit tre...

Page 6: ...t c rendement faible de la chemin e ouvrez le clapet de la chemin e v rifiez le raccordement de la chemin e nettoyez la chemin e teignez la capuche Fum e proximit du po le a rendement en sens inverse...

Page 7: ...s originale du fabricant Fabricant BURNING TECHNOLOGY a s Stupkova 952 18 Nov Ulice 77900 Olomouc 7 production mod le BURNING TECHNOLOGY a s Stupkova 952 18 Nov Ulice 77900 Olomouc info burn tech cz C...

Page 8: ...s de violation des tiquettes de garantie et des tiquettes portant des num ros de s rie Dommages la marchandise pendant le transport dans le cas de son propre transport En cas de transport par un prest...

Page 9: ...9 Instructions for Installation Use and Maintenance of a CARINA S Wood Burning Stove 09 2018...

Page 10: ...s used The stove is certified according to EN13240 Main heat and technical parameters Views and basic dimensions The primary and secondary air inlet is controlled with one lever under the door Total h...

Page 11: ...direction 1600 mm 3 General Safety Instructions Handle and unpack with caution and by safety instructions Burning fuel releases thermal energy resulting in a considerable heating of the surface of th...

Page 12: ...y is provided via an open window The stove has the possibility of supplying combustion air from the central air duct via a 99 mm diameter connection neck The connection neck is located at the bottom o...

Page 13: ...point b Old product Ceramic glass glass collection point Sealing rope mixed municipal waste Fireclay and heat plates sorted municipal waste Cast iron parts metal waste collection point Metal parts of...

Page 14: ...wood use dry hardwood b unheated stove heat up the stove to operating temperature open the combustion air supply lever more c door not sealing well change the door seal d glass not sealing well change...

Page 15: ...acturer s Manufacturer BURNING TECHNOLOGY info burn 15 Stupkova 952 18 Nov Ulice info burn tech cz CARINA S Wood burning BT 002B 001 2017 6 26 4 81 4 13 of O2 0 117 13 of O2 mg m3 1461 13 of O2 mg m3...

Page 16: ...o warranty labels and plates with serial numbers damage to goods during transport in the case of own transport In the case of transport by an external transport service the seller reserves the right t...

Page 17: ...17 Installations Bedienungs und Wartungsanleitung des Kaminofens CARINA S 09 2018...

Page 18: ...n istgem der Norm EN13240 zertifiziert Die w rmetechnischen Hauptparameter Ansichten und Grundma en Die Steuerung von der Prim r und Sekund rluftzufuhr erfolgt mit einem Hebel unter der T r Gesamth he...

Page 19: ...00 mm auf der R ckseite 600 mm in Strahlungsrichtung 800 mm Bei den leicht entflammbaren Materialien Asphaltplatte Polystyrol Holzfaserplatten halten Sie einen Mindestabstand ein zu Seiten 400 mm von...

Page 20: ...cht ffnen Sie das Fenster f r ein paar Minuten in der N he des Kaminofens bevor das Feuer entbrennt Reduzieren Sie die Verbrennungsluftzufuhr auf 20 Punkt d um mit der minimalen Leistung zu heizen Der...

Page 21: ...e die Schornsteintemperatur und den Brennprozess kontinuierlich L schen Sie das Feuer im Kaminofen niemals mit Wasser Wenn der Kaminofen in Betrieb ist muss die Feuerraumt re geschlossen werden damit...

Page 22: ...harten Hozl heizen b Der nicht aufgew rmte Kaminofen den Kaminofen auf Betriebstemperatur erhitzen c Der ungen gende Schornsteinzug die Schornsteinklappe ffnen den Schornsteinanschluss berpr fen den S...

Page 23: ...2 18 Nov Ulice 77900 Olomouc info burn 23 den Fall des hinteren Rauchabzuges Betriebs und Wartungsanleitung Muster BURNING TECHNOLOGY a s Stupkova 952 18 Nov Ulice 77900 Olomouc info burn tech cz 420...

Page 24: ...ebung entsprechen die M ngel die durch die Verletzung der Garantie und Typenschilder mit Seriennummern entstanden die Transportsch den bei dem eigenen Transport Bei einem Transport durch eine externe...

Page 25: ...25 N vod na instalaci obsluhu a dr bu krbov ch kamen CARINA S od 09 2018...

Page 26: ...na jsou certifikov ny podle normy EN13240 Hlavn teplo technick parametry Pohledy a z kladn rozm ry Ovl d n prim rn ho a sekund rn ho p vodu vzduchu je jednou p kou pod dv ky V ka celkov mm 1209 ka mm...

Page 27: ...a n mu zah t povrchu kamen dv ek spalovac ho prostoru kliky u dve a rukojet ovl dac ch prvk bezpe nostn ho skla kou ov ch potrub a p p eln st ny kamen Nedot kejte se t chto st bez p slu n ho ochrann h...

Page 28: ...t me p vod vzduchu pootev en m oknem Kamna maj mo nost p vodu spalovac ho vzduchu i z centr ln ho vzduchov ho veden pomoc spojovac ho hrdla pr m ru 99 mm Spojovac hrdlo je um stn no na kamnech ve spod...

Page 29: ...ho odpadu b Vyslou il v robek Keramick sklo sb rna skla T sn c ra sm sn komun ln odpad amotov a rov desky t d n komun ln odpad Litinov sti sb rna kovov ho odpadu Kovov sti krbu sb rna kovov ho odpadu...

Page 30: ...t such m tvrd m d evem b nerozeh t kamna rozeh t kamna na provozn teplotu otev t v ce p ku pro p vod spalovac ho vzduchu c net snic dv ka v m na t sn n dv ek d net sn c sklo v m na t sn n skla f Odbar...

Page 31: ...robce V robce 31 BURNING TECHNOLOGY a s Stupkova 952 18 Nov Ulice 7900 Olomouc info burn tech cz CARINA S Krbov kamna BT 002B 001 5 0004 B 2017 6 26 4 81 4 Koncentrace CO ve spalin ch p i 13 O2 0 117...

Page 32: ...or ch kter neodpov daj bytov mu prost ed p i poru en garan n ch n lepek a t tk s v robn mi sly na po kozen zbo p i p eprav v p pad vlastn p epravy V p pad p epravy extern dodavatelskou slu bou si prod...

Reviews: