29
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
TECHNICAL PASSPORT. INSTALLATION and OPERATION MANUAL
Diagram 19
- Carefully slide out the rail with the
burner mounted on.
Diagram 20
- The rail itself is hinge-fixed to the boiler
body, swing it to the right to withdraw
the burner from the boiler body.
Unscrew the marked bolts to dismount
the burner from the flange holding it
fixed to the rail.
Diagram 21
- Disassemble the burner combustion
chamber.
- Clean the inside of the burner chamber
thoroughly from residues. Use a bodkin
to release all clogged orifices along the
combustion chamber.
- Remove the ashes from inside the
burner. Use a vacuum cleaner and a
brush.
- Inspect and clean the motors and
sensors in the boiler.
- When mounting the burner back onto
the boiler, replace the seal between the
burner flange and the boiler.
9.3.4. Feeding auger:
- Completely empty the pellet hopper.
- Dismantle the auger from the pellet
hopper: release the top of the flexible
hose (
1
) from the auger tube; extract the
auger (
2
) by pulling it out of the hopper.
Diagram 22
- Clean the Auger from the ashes of the
transport of pellets: Dust off (
3
) and
clean the ashes from the collected (
4
)
- Mount the feeding auger back to the
pellet hopper.
Important! Fill Auger and
calibrate it. If auger remain
without fuel for transportation
will deteriorate normal boiler
operation.